Elimination of artifacts through spatial reconstitution in thoracic aorta imaging examination
Journal Title: Αρχεία Ελληνικής Ιατρικής - Year 2009, Vol 26, Issue 3
Abstract
OBJECTIVE The purpose of this study was to record streak artifacts appearing in chest imaging examinations and also to evaluate the possibility of eliminating or minimizing them through spatial reconstruction, for better visualization of the thoracic aorta. Streak artifacts are very common as examinations are performed with the use of IV contrast medium injection in high concentrations (350-370 mgI/mL), at injection rates of higher than 4 mL/sec and a fast scan time of the area of interest. METHOD A spiral CT (Philips 5000 SR) was used, with a scan time of 1.5 seconds per rotation and 40 chest examinations were included in the study, which were selected randomly during the program, whenever the images contained artifacts that could simulate pathology. An experienced radiologist selected the cases, and an experienced radiographer applied the spatial resolution. Two experienced radiologists performed quality evaluation in a double-blind study and four different image categories were created, according to the improvement of image quality. RESULTS In the first category (no improvement) were classified 17.5% of the cases namely none of the processed images improved with the spatial reconstruction method (less than 10% compared to the initial images). In the second category (slight improvement) were classified 35% of the cases. The scoring rate was better by a percentage of 11-35% compared to the initial images. In the third category (substantial improvement) were classified 27.5% of the cases. The scoring rate was better by a percentage of 36-70% compared to the initial images. In the fourth category (significant improvement) were classified a 25% of the cases. The scoring rate was better by a percentage of 71-100% compared to the initial images. CONCLUSIONS Spatial reconstruction, when applied to chest CT examinations, improves the quality of the image and contributes to the derivation of more accurate conclusions. This process for the correction of streak artifacts is suggested not only for safety reasons but also because it is difficult for an examination to be repeated on the same day due to the maximum dose of the contrast medium received.
Authors and Affiliations
E. LAVDAS, V. ROKA, G. PROTOGEROU, M. VLYCHOU, I. FEZOULIDIS
Alternative systems for the provision of pharmacologically assisted treatment of opioid dependence: from strict control to care in the community and Primary Health Care
According to the World Health Organization (WHO), the term «treatment» refers to a process, which commences when a patient contacts a health professional or a community service and which is maintained and further diversi...
Αντι-ιικά φάρμακα στη HIV-λοίμωξη<br /> Νεφροτοξικότητα και χορήγηση σε ασθενείς με νεφρική ανεπάρκεια
Οι ασθενείς με HIV-λοίμωξη υποβάλλονται σε ποικιλία θεραπευτικών σχημάτων για την υποκείμενη νόσο τους, αλλά και για καιροσκοπικές λοιμώξεις και κακοήθεις νόσους, που τη χαρακτηρίζουν. Η εισαγωγή νέων αντιρετρoϊκών φαρμά...
The qualitative evaluation of laboratory results
The significant progress made over the last decades in medicine, along with the explosion of information technology and biotechnology have led to the swift growth in laboratory techniques including use of new analyzers a...
Evidence-based medicine: Bayesian logic
Hypothesis tests and P values are used wrongly by most researchers for detecting relations and extracting conclusions in biomedical research. Over the last 20 years, systematic efforts are being made for the establishmen...
Female sexual response models
The recent development of the field of sexual medicine has necessitated the understanding of how women are motivated and function sexually. The term "sexual response cycle" refers to a model that depicts sexual function...