Energy Efficiency Assessment of Four Designs of Vertical Axis And Drag Differential Wind Turbines

Abstract

The present study compares the energy efficiency of four different wind turbine designs with vertical axis and differential drag, keeping equal their heights and diameters. Besides the classic two bladed Savonius model, two models derived from it were studied (Schulz and Beneshi), as well as the barely known Lenz type turbine. In laboratory tests of scale models the power curves have been determined as a function of the tip speed ratio, exposing the turbines to wind velocities up to 7 m/s. To avoid any variation in friction between tests, the same base, alternator and gears have been used for all four models. The Lenz model outperformed all others having the best power coefficient.

Authors and Affiliations

J. Pulfer, W. Meza, F. Mitjans

Keywords

Related Articles

Corrosion Monitoring and Detection Techniques in Petrochemical Refineries

Corrosion is defined as an attack on a material as a result of chemical, frequently electrochemical reaction, with the surrounding medium. Corrosion monitoring and detection provides comprising monitoring and detecting o...

State of Art on Short Term Load Forecasting Using Artificial Neural Network

Due to centralized power system and continuous varying nature of load it is very difficult to balance demand and generation at all time. It is due to the fact that generation can’t be controlled with the same pace as loa...

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

SEPIC topology based bidirectional DC-DC Converter is proposed for interfacing energy storage elements such as batteries & super capacitors with various power systems. This proposed bidirectional DC-DC converter acts as...

Closed Loop Control of the Three Switch Serial Input Interleaved Forward Converter Fed Dc Drive

This paper deals with the closed loop control of the three switch Interleaved Forward Converter with motor load. When any step change occurs at the input of the open loop three switch interleaved forward converter, the o...

Power Flow Control And Total Harmonic Distortion Reduction In HVDC Link Using PI And ANN Controllers

Long distance AC transmission is often subjected to certain problems which limit the transmission capability. HVDC is a better option for transmission of power over long distances. Power is being transmitted between two...

Download PDF file
  • EP ID EP388678
  • DOI 10.9790/1676-1301047381.
  • Views 113
  • Downloads 0

How To Cite

J. Pulfer, W. Meza, F. Mitjans (2018). Energy Efficiency Assessment of Four Designs of Vertical Axis And Drag Differential Wind Turbines. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(1), 73-81. https://europub.co.uk/articles/-A-388678