Energy-efficient combined shock-foam-type air-handling unit with block of thermoelectric modules for air conditioning systems
Journal Title: Budownictwo o zoptymalizowanym potencjale energetycznym - Year 2015, Vol 1, Issue 1
Abstract
The paper deals with the heat and mass transfer process research and calculation of the combined shock-foam-type air-handling unit with block of thermoelectric modules that create microclimate parameters during the museum pieces transportation and it storage in special premises. The air conditions variation range in airhandling unit is not limited to contact heating device, by combination of surface and contact heat exchangers in one construction, as well as turbulence in gas-liquid system provides intensification of the heat and mass transfer processes and air purification from impurities. However, combined shock-foam-type air-handling unit is compact, lightweight, energy efficient and make possible a temperature and cooling capacity variable control.
Authors and Affiliations
I. V. Chaban, Volodymyr B. Dovgalyuk
Analiza wad i zalet zastosowania ogrzewania podłogowego w obiektach sakralnych
Obiekty sakralne, ze względu na specyficzne cechy swoich wnętrz oraz krótkotrwałe i nieregularne ich użytkowanie, wymagają bardzo przemyślanego doboru rodzaju ogrzewania. W pracy dokonano analizy zalet i wad st...
Evaluation of the environmental safety of small Kazbegi HPP by considering the action of devdorak glacier formed in the bed of the river Kabakhi (Georgia)
Aiming at assessing the environmental safety of small Kazbegi HPP, we have described the catastrophic-scale mudflow formed as a result of movement of Devdorak glacier in the Gorge of the river Kabakhi (left tributary of...
Mnogoparametriceskaa optimizacia energoeffektivnosti grannyh zdanij (Multi-parameters optimization of the energy efficiency of cuboid buildings)
There has been presented a method of simultaneously optimizing of multiple energy efficient buildings parameters (shape, aspect ratio, heat loss resistance building envelope, building azimuth, etc.) to...
Quality evaluation of domestic hot water supply depending on location of the apartment in apartment building
The paper compares temperature of domestic hot water in households with various ascending pipes located on different floors in two residential buildings of the same structural system. It describes household e...
Ocena podatności kompozytów cementowych z wypełniaczami organicznymi na oddziaływanie CO2
W artykule przedstawiono wyniki badań nad właściwościami lekkich kompozytów cementowych z wypełniaczem organicznym typu trzcina pospolita ( Phragmites australis) oraz trociny z drzew iglastych, będące produktem odpado...