Enhancing the Efficiency of Air Conditioning Systems in High-Temperature Climates Through Direct Evaporative Cooling

Journal Title: Journal of Sustainability for Energy - Year 2024, Vol 3, Issue 2

Abstract

This study aims to develop energy-efficient and environmentally friendly cooling solutions that are both effective and adaptable to various climates and structural forms. By leveraging computational fluid dynamics (CFD) software ANSYS and simulation software Engineering Equation Solver (EES), an innovative approach was undertaken. The investigation focused on the optimization of external air cooling via adjustable injectors operating at three distinct velocities, across three airflow rates. Concurrently, the adaptability of the cooling flow was enhanced by varying the number of turns in a coil within the heat exchanger's condenser section. This dual-phase method facilitated a comprehensive analysis across 54 scenarios, employing the EES software for the calculation of the coefficient of performance (COP) enhancement metrics. The efficiency of the cooling apparatus was rigorously evaluated by methodically altering the number of cooling tube turns and injection velocities. The apparatus comprised a loop-and-tube heat exchanger with a modifiable structure, where the second phase of the study addressed the thermal impact of air entry velocity and water spray mechanisms, featuring cooling tube adjustments ranging from five to thirteen turns. The initial phase examined the effects of air entry area and water spray techniques through variable injector configurations, with diameters of 15, 24, and 20 cm, and dimensions of 10 cm in height and 25 cm in length, alongside a conduit width of 60 mm. The findings revealed that the thermal dynamics of the heat exchanger and fluid flow are significantly influenced by the apparatus's geometry, particularly the air entry area and water spraying mechanism. Temperature and velocity contours illustrated that the number of loop turns and injections markedly affects system performance. An optimal configuration, consisting of 35 injectors and 13 coil turns, achieved a COP of 4.537 at an inlet velocity of 2.0 m/s, signifying the most effective system design identified within this study.

Authors and Affiliations

Jaafar Saleem, Khaled M N Chahrour

Keywords

Related Articles

Improvement the Preparation of C4 Oolefin Through Ethanol Coupling and Optimization the Gray Correlation Degree Algorithm

C4 olefin is an important chemical raw material, but traditional production methods use limited and polluting fossil energy as raw materials. Ethanol stands out from many alternative energy sources because of its wide...

Experimental Exergy Analysis of Air Flow Through Micro Helical Tubes with Novel Geometries under Adiabatic Conditions

Helical microtubes are commonly used in micro-electronic cooling techniques and micro-heat exchangers because of the creation of secondary flows, which leads to greater temperature and velocity gradients. It is of great...

Enhanced Performance of Structurally Optimized Plate-Fin Heat Exchangers Through Numerical Modeling of Heat Transfer and Pressure Drop

This study aims to optimize the structure of compact Plate-Fin Heat Exchangers (PFHE) by incorporating corrugated fins and validating their improved performance through numerical modeling and simulation. The results prov...

Mixed Combustion Characteristics of Various Biomass Particles

As a promising pollutant emission reduction technology, biomass mixed combustion has attracted widespread attention worldwide. This paper aimed to study the characteristics of biomass mixed combustion and temperature dis...

Design and Economic Analysis of a Solar-Powered Charging Station for Personal Electric Vehicles in Indonesia

Indonesia, known for its abundant renewable resources, especially solar energy, presents a substantial potential for developing solar-powered solutions to meet its increasing electricity demands. This study explores the...

Download PDF file
  • EP ID EP744306
  • DOI https://doi.org/10.56578/jse030205
  • Views 11
  • Downloads 1

How To Cite

Jaafar Saleem, Khaled M N Chahrour (2024). Enhancing the Efficiency of Air Conditioning Systems in High-Temperature Climates Through Direct Evaporative Cooling. Journal of Sustainability for Energy, 3(2), -. https://europub.co.uk/articles/-A-744306