Abstract

A pulmonary artery catheter (PAC) is a useful tool for monitor haemodynamics during cardiac surgery in patients with compromised ventricular function and helps in the perioperative patient management. During open heart surgery entrapment of a Swan-Ganz catheter to an intracardiac structure is rare but may lead to potentially life-threatening complications. Here, we report a case of an entrapped pulmonary artery catheter by accidental surgical suturing at the entry point of Superior vena cava into right atrium that necessitated reopening the chest and removing the catheter.

Authors and Affiliations

Hariom Khandelwal, Kunal Singh, Ashutosh Singh, Parag Kumar

Keywords

Related Articles

Double inferior vena cava with L-type crossed fused renal ectopia: A rare case report

Duplication of the inferior vena cava (IVC), a rare anomaly reported to occur in 0.2-3% of the population and is known to be associated with various urogenital tract anomalies such as horseshoe kidneys, crossed fused ect...

Artemisin Combined Therapy in malaria patients: Do we need to search for more?

Introduction: Malaria is a vector borne disease highly prevalent in the topical developing countries. Two main species of plasmodium causing majority of diseases manifestations are P. Vivax and P. falciparum. The approac...

Additive effect of butorphanol in supraclavicular brachial plexus block

Introduction: Increasing the quality of regional anaesthesia has always been an area of interest for anaesthesiologist. Butorphanol is a synthetic opioid analgesic having partial agonist at μ & agonistic activity at kapp...

Predictors of long term survival after surgical resection in carcinoma gall bladder

Background-Carcinoma of the gallbladder is known to be associated with a dismal prognosis, with majority of patients presenting at late stages. Controversies still exist regarding the optimal management and the extent of...

High Sensitivity C-Reactive Protein an inflammatory marker and lipoprotein levels in patients with coronary heart disease

Background: C-Reactive Protein is a good marker of systemic inflammation which can be measured easily. Atherosclerosis lesions are intimal thickening of arteries. Inflammatory and immune cells constitute an important par...

Download PDF file
  • EP ID EP231007
  • DOI 10.17511
  • Views 90
  • Downloads 0

How To Cite

Hariom Khandelwal, Kunal Singh, Ashutosh Singh, Parag Kumar (2016). Entrapment of pulmonary artery catheter in superior vena caval cannulation site during cardiac surgery. International Journal of Medical Research and Review, 4(9), 1617-1619. https://europub.co.uk/articles/-A-231007