Establishment of internal quality control methodology for blood transfusion compatibility testing
Journal Title: Chinese Journal of Blood Transfusion - Year 2024, Vol 37, Issue 4
Abstract
Objective To monitor the effectiveness and accuracy of the blood transfusion compatibility test system by self-made weakly positive internal quality control products. Methods Red blood cells from DAT(-) healthy subjects were selected, and B/RhD(-)E(-) red blood cells were selected as tube 1. A/RhD(+ )E(+ ) was selected as tube 2 to prepare blood group quality control products according to the principle of blood group antigen compatibility, and red blood cell preservation solution and corresponding ABO blood group reagent antibody were added to make the agglutination intensity of microcolumn gel method in reverse blood typing reach a low positive value (1+ ). Tube 3 and tube 4 were prepared with five different preservation media: plasma, serum, antibody diluent, mixture of equal plasma and antibody diluent, and mixture of equal serum and antibody diluent, respectively. IgM anti-E antibody was added to tube 3, and IgG anti-D antibody was added to tube 4, so that the agglutination intensity of microcolumn gel method reached a low positive value (1+ ). Results Comparison between the 5 different preservation media showed that the preservation medium of antibody diluent was the most stable for weakly positive antibody (F=11.35, P<0.05), Agglutination intensity 1+ is assigned 5 points by AABB Technical Manual, and its score was 5.25±1.75 points. Conclusion The use of self-made weakly positive quality control products can improve the effectiveness, accuracy and sensitivity of the monitoring system, thus achieving internal quality control and ensuring the safety of clinical blood use.
Authors and Affiliations
Lu LI, Xiaolin SUN, Junjie WEI, Ruiqi LIU, Weixin WU, Haiyun Liu, Yinze ZHANG
Factors affecting the efficacy of platelet transfusion and specificity of HLA-Ⅰ antibodies in tumor patients
Objective To analyze the factors affecting the efficacy of platelet transfusion and the specificity of HLA-Ⅰ antibodies in tumor patients. Methods Tumer patients applied for platelet transfusion from November 2019 to Jul...
Establishment and evaluation of a competitive performance evaluation system for blood centers
Objective To investigate the establishment of a competitive performance evaluation management program for blood centers to ensure the blood supply. Methods A competitive performance evaluation system for Blood Donor Serv...
Influencing factors of the repeat reactive (RR) rates of minipools implicated in minipool(MP) nucleic acid testing(NAT) in Xiamen
Objective To analyze the influencing factors of the repeat reactive (RR) rates of minipools implicated in minipool (MP) nucleic acid testing(NAT) in Xiamen Blood Center, in order to provide reference for NAT. Methods Sam...
Following up and re-entry of HBV reactive blood donors in Yantai area
Objective To analyze the preliminary screening and follow-up testing data of HBV in Yantai area, and discuss the rationality of following up and re-entry program of HBV reactive blood donors. Methods Donors who were sing...
Establishment of reference intervals for serum sTfR and sTfR/lgSF in apparently healthy adults in Wuhan
Objective To establish reference intervals for serum soluble transferrin receptor (sTfR) and sTfR/log serum ferritin index (sTfR/lgSF) in apparently healthy adults in the Wuhan area, so as to provide reference for clinic...