Estimation of Cooling Load Calculations for a Commercial Complex

Abstract

In this project we discussed the cooling load calculations for a commercial building by using revit software Window air conditioners, split air conditioners are used in small buildings and offices etc but in big buildings and commercial complex we use central air conditioning systems this systems are installed far away from the buildings. The cooled air is supplied to the building with the help of ducts. When ducts are not properly designed, then it will lead to problem such as frictional loss, higher installation cost, increased noise and power consumption. For minimizing this problem, a proper design of duct is needed. Equal friction method is used to design the duct it gives the comparison of pressure drop in rectangular duct and circular duct. Central air conditioning is more reliable for easy operation with a lower maintenance cost. Cooling load items such as, people heat gain, lighting heat gain, infiltration and ventilation heat gain can easily by using REVIT SOFTWARE. The programme can also be used to calculate cooling load due to walls and roofs. And results were compared with the standard data given by ASHRAE and CARRIER. The RULE OF THUMB method is used to calculate the heat developed in the rooms. These methods are used for lower power consumption capital cost and improve aesthetics of building by I. S. N. V. R. Prashanth | V. Nikitha | B. Aravind | N. Mahesh "Estimation of Cooling Load Calculations for a Commercial Complex" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-3 , April 2019, URL: https://www.ijtsrd.com/papers/ijtsrd23322.pdf Paper URL: https://www.ijtsrd.com/engineering/mechanical-engineering/23322/estimation-of-cooling-load-calculations-for-a-commercial-complex/i-s-n-v-r-prashanth

Authors and Affiliations

Keywords

Related Articles

Review Paper on Predicting Network Attack Patterns in SDN using ML

Software Defined Networking SDN provides several advantages like manageability, scaling, and improved performance. SDN has some security problems, especially if its controller is defense less over Distributed Denial of S...

Human Trafficking in India

Human trafficking is the third largest organised crime after drugs and arms trade across the globe. 80% of Human Trafficking across the globe is for sexual exploitation. Human trafficking is one of the major problems in...

Effect of Foreign Exchange Rate Fluctuations on Nigerian Economy

This study investigated the effect of exchange rate fluctuations on Nigerian economy. The fixed and floating exchange eras were compared to know the exchange rate system in which the economy has fairly better. The time p...

Flexural Behaviour of Steel Fiber Reinforced GEO Polymer Concrete

Concrete is the most used development fabric from historic days. It used to be anticipated that the manufacturing of cement would be accelerated from about from 1.5 billion lots in 1995 to 2.2 billion lots in 2020. But 2...

"All Is Well, That Ends Well"- Stylistic Features and Shakespearean Language

The article describes the peculiarities of distinctive points of writer"-™s style, utilization of expressive means and grammatical deviations. The author focuses on the findings from the play "All is well, that ends well...

Download PDF file
  • EP ID EP586194
  • DOI 10.31142/ijtsrd23322
  • Views 170
  • Downloads 0

How To Cite

(2019). Estimation of Cooling Load Calculations for a Commercial Complex. International Journal of Trend in Scientific Research and Development, 3(3), 1229-1232. https://europub.co.uk/articles/-A-586194