Abstract

Objective: The objective of this study was to estimate the entrance surface radiation dose to the thyroid region in a computed tomography (CT) brain scan.Methods: Unfors Multi-O-Meter equipment was used to measure the entrance surface at the thyroid region of adult patients ranging from 18 to 70 years of age. A total of 115 patients were included in the study based on convenience sampling. The Multi-O-Meter was kept at the thyroid region during the scan, and the values for entrance surface dose (ESD) were noted from its monitor after the scan was complete.Results: The obtained data were analyzed and violate normal distribution; therefore, the median and quartiles were computed. The overall median (Q1, Q2), ESD of the patients, was 1.335 (1.213, 1.529) mGy. The minimum and maximum dose values recorded were 1.015 mGy and 1.964 mGy, respectively.Conclusions: The result showed a significant amount of entrance surface radiation dose to the thyroid region while taking a brain scan. This data can be used for optimization of radiation protection while undergoing CT scans of brain to reduce exposure to thyroid region.

Authors and Affiliations

Visakh T, Suresh Sukumar, Abhimanyu Pradhan

Keywords

Related Articles

A REVIEW ON BIOGENIC PROPERTIES OF STEM BARK OF TERMINALIA ARJUNA: AN UPDATE

The traditional and alternative systems of medicine have been resulting more than 85% of the drugs from a plant source. Terminalia arjuna (T. arjuna) stem bark contain glycosides, ample quantities of flavonoids, tannins,...

P-SELECTIN GLYCOPROTEIN LIGAND-1 GENE POLYMORPHISMS IN SUDANESE PREGNANT WOMEN WITH THROMBOSIS

Objectives: In this study we aimed to investigate whether P-selectin gene polymorphism is associated with thrombosis in Sudanese pregnant women in Khartoum state.Methods: After informed consent, 96 Sudanese pregnant wome...

IN VITRO ANTIOXIDANT AND CYTOTOXIC PROPERTIES OF FUCOIDAN FROM THREE INDIAN BROWN SEAWEEDS

Objective: In the present study, fucoidan extracted from three brown algae, Sargassum wightii, Turbinaria ornata, and Padina tetrastromatica, was purified, characterized, and evaluated for antioxidant and cytotoxic prope...

SYNTHESIS, BIOLOGICAL EVALUATION, AND DOCKING STUDY OF NOVEL 2-PHENYL-1- BENZOPYRAN-4-ONE DERIVATIVES - AS A POTENT CYCLOOXYGENASE-2 INHIBITOR

Objective: The inflammation and oxidative stress were related together in the generation of reactive oxygen species, which is responsible for the enhancement of inflammation associated with various chronic diseases. Met...

A STUDY ON PATIENTS’ AWARENESS, RECOGNITION MANAGEMENT AND PREVALENCE OF HYPOGLYCEMIC EPISODES IN TYPE 2 DIABETES MELLITUS IN A TERTIARY CARE HOSPITAL

Objective: To assess patients’ awareness on management of hypoglycemic episodes and analyzing the prevalence of hypoglycemic episodes inpatients with Type 2 diabetes mellitus.Methods: A prospective-observational compar...

Download PDF file
  • EP ID EP607109
  • DOI 10.22159/ajpcr.2019.v12i1.28932
  • Views 116
  • Downloads 0

How To Cite

Visakh T, Suresh Sukumar, Abhimanyu Pradhan (2019). ESTIMATION OF ENTRANCE SURFACE RADIATION DOSE TO THYROID REGION IN COMPUTED TOMOGRAPHY BRAIN EXAMINATION. Asian Journal of Pharamceutical and Clinical Research, 12(1), 121-123. https://europub.co.uk/articles/-A-607109