EVALUATION COMPARISON IMAGE QUALITY OF BREATH HOLD (SSTSE) AND RESPIRATORY TRIGGERING (TSE) TECHNIQUE TO THE EXAMINATION OF MAGNETIC CHOLANGIOPANCREATOGRAPHY (MRCP)

Journal Title: Journal of Vocational Health Studies - Year 2017, Vol 1, Issue 2

Abstract

Background : Magnetic resonance cholangiopancreatography (MRCP) is MRI examination to visualize to visualize a disorder in part biliary or of the human bile. The artefact in the image MRCP is often happened due to the movement of respiratory system. Purpose : This study to compare the better image quality between Breath Hold (SSTSE) and Repiratory Triggering (TSE)techinques. Methods : This study used observational analytic study with prospective approach. 16 samples were examined with two techniques SSTSE and TSE respectively in order to get 3D MRCP image. The Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) is measured to evaluate the image quality. Result: The SSTSE technique only has a higher SNR in gallbladder meanwhile the TSE technique has a higher SNR in pancreatic duct. The higher CNR is got using TSE technique. Conclusion : The TSE showed the higher SNR in pancreatic duct and the higher CNR is got with SSTSE technique. The recommendation technique for evaluating pancreatic duct is respiratory triggering.

Authors and Affiliations

Nikky Anis S. , Risalatul Latifah, Sri Andreani U.

Keywords

Related Articles

MANUFACTURING TECHNIQUE OF METAL CERAMIC RESTORATION WITH IMPLANT-ABUTMENT AT GINGIVAL RESORPTION CASE

Background: The low levels of patient satisfaction and confidence in the restoration of the gingival resorption results in impaired quality of life in both functional and psychosocial aspects. It is necessary to manufact...

CHENGQI, TONGZILIAO AND YINTANG POINT ACUPUNCTURE IN IMPROVING THE CASE OF MYOPIA VISUS

Background: Myopia, commonly referred to as shortsightedness, is one of the top five causes of blindness worldwide. It is said that in patients with myopia, intraocular pressure has a relationship that tends to increase...

THE CORRELATION OF CHEMICAL EXPOSURE AND PERSONAL HYGIENE WITH IRRITANT CONTACT DERMATITIS AMONG WORKERS IN THE PRODUCTION WORKER

Background: The production process at PT. X using oxalic acid as a mixture of Gum Rosin and Turpentine. Oxalic acid is corrosive and toxic and readily oxidized by water and oxygen that can cause irritation, rashes, burns...

EVALUATION COMPARISON IMAGE QUALITY OF BREATH HOLD (SSTSE) AND RESPIRATORY TRIGGERING (TSE) TECHNIQUE TO THE EXAMINATION OF MAGNETIC CHOLANGIOPANCREATOGRAPHY (MRCP)

Background : Magnetic resonance cholangiopancreatography (MRCP) is MRI examination to visualize to visualize a disorder in part biliary or of the human bile. The artefact in the image MRCP is often happened due to the mo...

FABRICATION TECHNIQUE OF DENTAL RESTORATION USING HYBRID CERAMIC WITH CAD CAM METHOD

Background : Ceramic is superior in aesthetic but fragile and breakable under bite pressure . Lack of understanding of material requirements for resistance in the oral cavity and minimal ceramic processing techniques is...

Download PDF file
  • EP ID EP594101
  • DOI 10.20473/jvhs.V1.I2.2017.39-43
  • Views 325
  • Downloads 0

How To Cite

Nikky Anis S. , Risalatul Latifah, Sri Andreani U. (2017). EVALUATION COMPARISON IMAGE QUALITY OF BREATH HOLD (SSTSE) AND RESPIRATORY TRIGGERING (TSE) TECHNIQUE TO THE EXAMINATION OF MAGNETIC CHOLANGIOPANCREATOGRAPHY (MRCP). Journal of Vocational Health Studies, 1(2), 39-43. https://europub.co.uk/articles/-A-594101