Evaluation of changes in IOP and anterior chamber parameters post laser irodotomy using pentacam system

Journal Title: Indian Journal of Clinical and Experimental Ophthalmology - Year 2017, Vol 3, Issue 4

Abstract

ntroduction: Aim of the study was to evaluate IOP changes and anterior chamber parameters (depth and volume), in primary angle closure (PAC) cases after laser peripheral irodotomy (LPI) using Pentacam system in OPD patients at Govt. Medical College, Patiala. Material and Methods: Total 12 eyes of 12 PAC patients were analysed in the study in the period of 3 months from March 2017 to May 2017. LPI was performed on the enrolled eyes, Pentacam system was used to calculate anterior chamber and IOP changes pre and post 14 days of LPI treatment. Results: There was statistically significant difference before LPI and after LPI for all measured variables. The mean ACD and ACV increased by p=0.04 and p = 0.001 respectively in 12 patients. The mean IOP decreased in all eyes with p=0.03 at month 3 and thereafter. Conclusion: In conclusion, LPI produces significant anterior chamber depth & volume along with decrease in IOP making LPI effective in treatment of primary angle closure cases.

Authors and Affiliations

Monika Kharbanda, Ishwar Singh, Sachin Walia, Harsimran Singh

Keywords

Related Articles

A comparative study of noncycloplegic automated refraction, cycloplegic automated refraction and cycloplegic refraction among youngsters

Purpose: Comparative studies of noncycloplegic automated refraction, cycloplegic automated refraction and cycloplegic refraction among youngsters are scanty. This study aimed to compare noncycloplegic AR, cycloplegic AR...

Hearing Impairment in pseudoexfoliation syndrome

Aim to compare the degree of sensorineural hearing loss in patients with and without pseudo exfoliationMaterials and Methods A comparative study design enrolling 44 patients each with and without pseudoexfoliation was em...

Evaluation of endothelial cell density and central corneal thickness in cases of pseudoexfoliation

Background: Aim of the study is to evaluate endothelial cell density and central corneal thickness in cases of pseudoexfoliation admitted for cataract surgery in tertiary care hospital using specular microscopy. Material...

A comparative study of endothelial cell loss in cataract surgery: small incision cataract surgery versus phacoemulsification

Aim: The purpose of the study was to study and compare the endothelial cell loss in small incision cataract surgery and phacoemulsification. Materials and Methods: A total of 200 cases were randomly selected and were div...

Pediatric cataract blindness management and outcomes in North East India – hospital based study

Purpose: To study the visual outcomes and cause of poor visual prognosis in pediatric cataract patients in North East India. Methods: Retrospective analyses of 283 eyes of patients with cataract below age of 18 years wit...

Download PDF file
  • EP ID EP301384
  • DOI 10.18231/2395-1451.2017.0103
  • Views 95
  • Downloads 0

How To Cite

Monika Kharbanda, Ishwar Singh, Sachin Walia, Harsimran Singh (2017). Evaluation of changes in IOP and anterior chamber parameters post laser irodotomy using pentacam system. Indian Journal of Clinical and Experimental Ophthalmology, 3(4), 419-421. https://europub.co.uk/articles/-A-301384