Evaluation of Compressive Strength and Sorption/Solubility of Four Luting Cements
Journal Title: Journal of Dental Biomaterials - Year 2017, Vol 4, Issue 2
Abstract
Statement of Problem: Compressive strength (CS) and sorption/solubility of the luting cements are two associated factors. Searching a correlation between sorption/solubility and compressive strength of various luting cements is required. Objectives: To measure the water sorption/solubility, and compressive strength of three resin-based and one conventional glass ionomer (CGI) luting cement after 1 and 24 h of immersion in distilled water and to determine if there is any correlation between those properties found. Materials and Methods: Four luting cements were investigated. For each material, 10 disc shaped specimens were prepared for measuring the sorption/solubility. The specimens were cured according to the manufacturer’s instructions, and the sorption/solubility were measured in accordance with the ISO 4049’s. For testing the compression strength, for each material 16 cylindrical specimens were prepared by insertion of cements into a stainless steel split mould. The specimens were cured, divided into groups of 8, and then stored in distilled water at (37 ± 1)°C for 1 and 24 h. The test was performed using the universal testing machine, the maximum load was recorded and CS was calculated. The data were analysed using SPSS software version 18. One-way ANOVA, post-hoc Tukey’s test and Pearson’s correlation coefficient were performed. Results: G-CEM had the highest mean CS (153.60± 25.15) and CGI luting had the lowest CS (21.36±5.37) (p <0.001). After 24 h, mean CS values showed an increase for almost all materials except for RelyXTM U200 which showed a slight reduction. However, no statistically significant difference was founded (all p > 0.05). The lowest mean sorption/solubility value was for RelyXTM U200 and Panavia F, and the highest for CGI luting (all p < 0.001). Conclusions: The compressive strength of all cements did not necessarily increase after 24 h and varied depending on the materials. There was a strong reverse correlation between sorption and CS values after both 1 and 24 h immersion. It may be practical for clinician to use those cements with the less sorption / solubility and more stable compression strength over time.
Authors and Affiliations
M Tavangar, D Jafarpur, R Bagheri
A Comparison of Push-Out Bond Strength of Two Endodontic Sealers to Root Canal Dentin: An in Vitro Study
Statement of Problem: Adhesion to root canal dentin is one of the necessary characteristics of endodontic sealers. MTA Fillapex (Angelus, Londria, PR, Brazil) is one of the recently introduced MTA-based sealer. Only a li...
Fracture Toughness of Nanohybrid and Hybrid Composites Stored Wet and Dry up to 60 Days
ABSTRACT Statement of Problem: Patients’ demand for tooth-colored restoratives in the posterior region is increasing. Clinicians use universal nanohybrid resin composites for both anterior and posterior regions. There ar...
Finite Element Analysis of the Effect of Superstructure Materials and Loading Angle on Stress Distribution around the Implant
Statement of Problem: A general process in implant design is to determine the reason of possible problems and to find the relevant solutions. The success of the implant depends on the control technique of implant biomech...