Evaluation of direct reading photoionization detector performance under various operational parameters

Journal Title: Environmental Health Engineering and Management Journal - Year 2021, Vol 8, Issue 2

Abstract

Background: A hand-held portable direct-reading monitor, including photoionization detector (PID) is renowned for its good sensitivity, considerable dynamic range, and nondestructive vapor detection ability in comparison to the tardy response of the PID in gas chromatography (GC), which its application has been restricted. In this study, the performance of a PID system (MultiRAE Lite) was evaluated as a replacement of GC in the measurement of toluene in a dynamic adsorption system. Methods: The test was done at different relative humidity levels (30%, 50%, and 80%), temperatures (21, 30, 40°C), and toluene concentrations (20, 100, 200, and 400 ppm). Results: The PID achieved 48% of all measurements meeting the comparison criterion. The results showed that the performance of the PID could be altered by the variables. The best performance of the PID was at temperature of 21°C, the relative humidity of 50%, and concentration of 200 ppm with the percentage of readings achieving the criterion of comparison to 58%, 54%, and 52%, respectively. The averages of the PID readings (mean ± SD at 200 ppm= 207.9 ± 8.7) were higher than the reference method measurements averages (mean ± SD at 200 ppm= 203.5 ± 5.8). The regression analysis of the toluene results from the PID and the reference method results indicated that the measurements were significantly correlated (r2 = 0.93). Conclusion: According to the results, the device response is linear. Therefore, the findings are acceptable in adsorption studies. In this way, the measurement of the sample concentration should be performed using the same instrument before and after the reactor in order to calculate the adsorption efficiency.

Authors and Affiliations

Amir Hossein Khoshakhlagh, Farideh Golbabaei, Mojtaba Beygzadeh, Francisco Carrasco-Marín, Seyed Jamaleddin Shahtaheri

Keywords

Related Articles

Association of urinary triclosan and methyl-triclosan levels with predictive indicators of cardiovascular disease and obesity in children and adolescents in 2020 (case study: Kerman, Iran)

Background: Exposure of children and adolescents to endocrine disrupting chemicals (EDCs) causes the development of non-communicable diseases. Triclosan (TCS) is a fat-soluble antimicrobial agent, and methyl-triclosan...

Investigation of toxicity of TiO2 nanoparticles on glioblastoma and neuroblastoma as the most widely used nanoparticles in photocatalytic processes

Background: Titanium dioxide (TiO2) nanoparticles (NPs) are among the most important and usable photocatalysts. Recently, the biological properties of these NPs, particularly, its anticancer activity, have been conside...

Biomedical waste disposal systems of health facilities in Ethiopia

Background: Biomedical waste generated from health and health-related activities can be grouped as general waste and hazardous waste. This remains true if and only if there is proper on-site handling, such as the segrega...

Assessment of the impact of tourism attractions with an emphasis on economic and environmental sustainable: A case study in Isfahan

Background: Tourism is an industry whose development requires knowledge and enough understanding of the issues and factors affecting the economy, culture, and environment. This study aimed to identify the impact of tou...

Arsenic and heavy metal concentrations in human hair from urban areas

Background: As concentrations of heavy metals in hair can reflect both metals exposure and intake concentrations, hair sample analysis is widely applied in forensic sciences, evaluation of environmental or occupational...

Download PDF file
  • EP ID EP695565
  • DOI 10.34172/EHEM.2021.15
  • Views 114
  • Downloads 0

How To Cite

Amir Hossein Khoshakhlagh, Farideh Golbabaei, Mojtaba Beygzadeh, Francisco Carrasco-Marín, Seyed Jamaleddin Shahtaheri (2021). Evaluation of direct reading photoionization detector performance under various operational parameters. Environmental Health Engineering and Management Journal, 8(2), -. https://europub.co.uk/articles/-A-695565