Evaluation of direct reading photoionization detector performance under various operational parameters
Journal Title: Environmental Health Engineering and Management Journal - Year 2021, Vol 8, Issue 2
Abstract
Background: A hand-held portable direct-reading monitor, including photoionization detector (PID) is renowned for its good sensitivity, considerable dynamic range, and nondestructive vapor detection ability in comparison to the tardy response of the PID in gas chromatography (GC), which its application has been restricted. In this study, the performance of a PID system (MultiRAE Lite) was evaluated as a replacement of GC in the measurement of toluene in a dynamic adsorption system. Methods: The test was done at different relative humidity levels (30%, 50%, and 80%), temperatures (21, 30, 40°C), and toluene concentrations (20, 100, 200, and 400 ppm). Results: The PID achieved 48% of all measurements meeting the comparison criterion. The results showed that the performance of the PID could be altered by the variables. The best performance of the PID was at temperature of 21°C, the relative humidity of 50%, and concentration of 200 ppm with the percentage of readings achieving the criterion of comparison to 58%, 54%, and 52%, respectively. The averages of the PID readings (mean ± SD at 200 ppm= 207.9 ± 8.7) were higher than the reference method measurements averages (mean ± SD at 200 ppm= 203.5 ± 5.8). The regression analysis of the toluene results from the PID and the reference method results indicated that the measurements were significantly correlated (r2 = 0.93). Conclusion: According to the results, the device response is linear. Therefore, the findings are acceptable in adsorption studies. In this way, the measurement of the sample concentration should be performed using the same instrument before and after the reactor in order to calculate the adsorption efficiency.
Authors and Affiliations
Amir Hossein Khoshakhlagh, Farideh Golbabaei, Mojtaba Beygzadeh, Francisco Carrasco-Marín, Seyed Jamaleddin Shahtaheri
Risk assessment of noise pollution by analyzing the level of sound loudness resulting from central traffic in Shiraz
Background: Today, the effects of environmental pollution on human life and human needs, which reduces the level of community health caused by traffic noise in large cities, are clearly visible by creating irritation and...
Neglect of other health services during the corona crisis
This article does not have abstract
Application of imputation methods for missing values of PM10 and O3 data: Interpolation, moving average and K-nearest neighbor methods
Background: PIn air quality studies, it is very often to have missing data due to reasons such as machine failure or human error. The approach used in dealing with such missing data can affect the results of the analys...
Photocatalytic removal of Malachite green dye from aqueous solutions by nano-composites containing titanium dioxide: A systematic review
Background: Malachite green (MG) is widely used as a fungicide, Bactericide parasiticide in the aquaculture industry, as a food additive, medical disinfectant, and also, as a dye for materials such as silk, leather, pape...
Enhanced electro-Fenton processes by persulfate radical for atenolol oxidation from aqueous solution
Background: Pharmaceuticals and personal care products (PPCPs) are a group of emerging environmental pollutants that have attracted the attention of many researchers due to their harmful effects on aquatic environment, a...