Evaluation of frictional forces generated in retrieved aesthetic wires with different ligation methods

Journal Title: Journal of Dental Specialities - Year 2016, Vol 4, Issue 1

Abstract

Objective: To evaluate frictional forces generated in retrieved aesthetic archwires with different ligation methods. Materials and Method: A total of 40(20 new and 20 retrieved from the patient’s mouth) Teflon coated 019X025 Stainless steel archwires and 40(20 new and 20 retrieved from the patient’s mouth) conventional 019X025 Stainless steel archwires were used for the study. The retrieved archwires were cleaned in ultrasonic cleaner for 15 minutes and placed in glutaraldehyde solution for one hour. A jig was formed using ceramic brackets without metal slot and a molar tube for the purpose of evaluation of friction forces. The wires were ligated with either stainless steel ligatures or elastomeric modules. The values obtained were subjected to Mann Whitney and Wilcoxon Sign rank test for statistical analysis. Results: The frictional values for conventional Stainless steel wires was less than Teflon coated wires in case of new wires. In case of retrieved archwires there was no difference between conventional or Teflon coated wires. The amount of friction for both Teflon coated and conventional wires decreased on retrieved from the patient. In case of Teflon coated wires the friction was greater with ligatures as compared to modules while in case of conventional Stainless steel wires it was vice-versa. Conclusion: Teflon coated wires when cleaned in ultrasonic cleaner showed reduction in frictional forces with no significant difference in friction generated by both methods of ligation.

Authors and Affiliations

Rabinder Kaur, Piush Kumar, Payal Sharma, Shalaj Bhatnagar

Keywords

Related Articles

Comparison of clinical characteristics of conventional and nickel free metal brackets before and after recycling

Objective To compare the clinical characteristics of conventional and Nickelfree metal brackets before and after recyclingMaterials and Method Total of 25 Nickelfree CoCr alloy premolar brackets MBT 0022 slot and equal n...

Aspirin induced intraoral burn: A rare case report with emphasis on its diagnosis

Introduction We present a case of chemical burn due to use of aspirin for pain control as selfmedication A patient placed Aspirin tablet in the right posterior lingual vestibule A diagnosis of chemical burn was made base...

Peripheral Ossifying Fibroma: A rare case report

Peripheral ossifying fibroma (POF) is a type of non-neoplastic gingival enlargement which shows areas of calcification or ossification. It is reactive lesion which usually arises from interdental gingiva and mostly in th...

Rehabilitation of a case of enucleated retinoblastoma

Retinoblastoma is one of the commonest malignant intraocular tumors in pediatric population, resulting in evisceration, enucleation or exenteration of orbital contents. An ocular prosthesis can boost the psychological we...

Phenytoin – induced gingival overgrowth: a case report

Drug-induced gingival overgrowth (DIGO) is a common clinical finding which can be treated either by nonsurgical and/or surgical techniques which will reduce the rate of recurrence. Wherever possible the required manageme...

Download PDF file
  • EP ID EP242263
  • DOI -
  • Views 52
  • Downloads 0

How To Cite

Rabinder Kaur, Piush Kumar, Payal Sharma, Shalaj Bhatnagar (2016). Evaluation of frictional forces generated in retrieved aesthetic wires with different ligation methods. Journal of Dental Specialities, 4(1), 26-30. https://europub.co.uk/articles/-A-242263