Evaluation of Implant Overdenture Retention with Two Different Attachments at 23mm Standard Inter-Implant Distance

Journal Title: Journal of Dentistry and Oral Sciences - Year 2020, Vol 2, Issue 2

Abstract

Purpose: Evaluation of implant overdenture retention at 23mm standard inter-implant distance using OT Equator and locator attachments. Materials and methods: Twelve completely edentulous patients were selected for this study. For all patients, conventional complete dentures were constructed. Mandibular dentures were replicated into stereolithographic implant placement guide using CBCT. Every participant received 2-implants in the anterior mandibular area with inter-implant distance of 23 mm. After the osseointegration period, the mandibular conventional dentures were converted into implant retained overdentures attached with Locator attachment for (group I) (six patients) and OT Equator attachments for (group II) (six patients). Retention was evaluated for conventional mandibular complete dentures (T0), 3-months (T3) and, 6-months (T6) after overdenture insertion using digital force-meter. Results: Results revealed that there was a statistically significant difference between the study groups representing mean retention force (P<0.05) except at T0 (baseline evaluation with conventional dentures) with higher mean values for group I (Locator attachment) than group II (OT Equator attachment). Conclusion: Regarding the limitations of this study: -Inter-implant distance of 23 mm for 2-implant overdentures could be considered a reliable modality for edentulous mandible. -Locator attachment may be preferable than OT Equator attachment regarding 2-implant overdenture retention at 23 mm inter-implant distance.

Authors and Affiliations

Hassan Ali Hassan1, Radwa MK Emera2*, Wael S Ahmed 3 and Nesreen El Mekawy4

Keywords

Related Articles

Editor Note

It is with great delight to introduce you "Journal of Dentistry and Oral Sciences", the journal aiming to publish works of great distinctions in the area of dentistry. The intention of this journal is to bring broader in...

A Novel Approach to Restore a Decayed Mandibular Posterior Tooth by Immediate Implant Placement Using Autogenous Tooth Graft Material Mixed with Platelet-Rich Fibrin: A Case Report

A dental implant is the most accepted treatment option to replace the badly decayed tooth or missing tooth. The jumping gap left after the placement of the implant in the socket will require augmentation of bone graft m...

Pleomorphic Adenoma of Palate - A Case Report and Review of Literature

10% of pleomorphic adenomas occur in the minor salivary glands with the palate being the most common site. Pleomorphic adenomas account for the majority of palatal tumors; however, minor salivary gland tumours have a hig...

Indicators and Preferences of Facial Profile and Aesthetics

For a successful orthodontic treatment, it is crucial to examine the patient in both frontal and lateral views. Evaluation of the skeletal pattern and softs tissues including nasolabial angle, anteroposterior lip positio...

Double Layer Socket Preservation Technique Associated with Xenogenous Bone Graft and Polypropylene Membrane: A Case Report

With the demand for tooth/gum aesthetics in implant-supported rehabilitations, the surgeon, whether an implant specialist or not, increasingly needs to be mindful of proper care for socket preservation following extracti...

Download PDF file
  • EP ID EP707461
  • DOI https://doi.org/10.37191/Mapsci-2582-3736-2(2)-026
  • Views 53
  • Downloads 0

How To Cite

Hassan Ali Hassan1, Radwa MK Emera2*, Wael S Ahmed 3 and Nesreen El Mekawy4 (2020). Evaluation of Implant Overdenture Retention with Two Different Attachments at 23mm Standard Inter-Implant Distance. Journal of Dentistry and Oral Sciences, 2(2), -. https://europub.co.uk/articles/-A-707461