Evaluation of Sensibility Threshold of Dental Pulp to Electric Pulp Test (EPT) in the Teeth under Fixed Orthodontic Treatment with 0.014 and 0.012 Initial NiTi Archwire

Journal Title: Journal of Clinical and Diagnostic Research - Year 2019, Vol 13, Issue 1

Abstract

ABSTRACT Introduction: The health and integrity of the dental pulp following orthodontic therapy is of major importance for tooth survival. EPT is a conventional method for evaluation of pulp vitality. Aim: The aim of the study was to evaluate sensibility of the dental pulp to EPT in the teeth under fixed orthodontic treatment with 0.014 and 0.012 initial NiTi archwire. Materials and Methods: In this study, 516 teeth (maxillary central and lateral incisors) were studied prospectively in 129 patients assigned to three groups: the 0.012 NiTi archwire, the 0.014 NiTi archwire and the control group. The aligning forces were administered using initial NiTi archwires of 0.012 and 0.014 ligated on fixed appliances by using the MBT straight wire technique. Stimulation of electrical sensibility threshold was done by EPT and was measured pre-bonding (EPT0), immediately upon initiation (EPT1) and one month post orthodontic therapy (EPT2). The data were analysed by paired sample t-test and one-way ANOVA test (p<0.05). Results: The mean values of sensibility threshold for all the experimental and control maxillary incisors at EPT0, EPT1, and EPT2 times were 28.5, 40.8, and 38.0, and 23.2, 23.5, and 22.7 units respectively. The mean values of sensibility threshold for all experimental teeth at EPT0, EPT1 and EPT2 times were statistically different by using Paired sample t-test (p<0.05). Statistical analysis using one-way ANOVA shows that there is a statistically significant difference between sensibility threshold when groups were compared with the control group (p<0.05). Conclusion: Following application of orthodontic forces, physiological changes of the dental pulp could affect the neural response. Response thresholds to electrical stimulation are also increased and consequently the EPT may not initiate a response. This finding is not an indication of loss of pulp vitality because after a few weeks the response threshold decreases. Therefore, the results of electrical pulp testing need to be carefully interpreted and closely scrutinised in orthodontics.

Authors and Affiliations

Elham Khoshbin, Sepideh Soheilifar, Zakiyeh Donyavi, Nazanin Shahsavand

Keywords

Related Articles

SEM Evaluation of Enamel Surface Changes and Enamel Microhardness around Orthodontic Brackets after Application of CO2 Laser, Er,Cr:YSGG Laser and Fluoride Varnish: An In vivo Study

Introduction: One of the most undesirable consequences of orthodontic treatment is occurrence of enamel demineralization around orthodontic brackets. Numerous in vitro studies have reported the prevention of enamel demin...

Oncogenic Osteomalacia: An Approach to Diagnosis with a Case Report

Oncogenic osteomalacia, also known as tumour induced osteomalacia, is a rare paraneoplastic syndrome caused by mesenchymal tumours secreting Fibroblast Growth Factor-23 (FGF-23). The characteristic biochemical findings i...

Small Incision Osteotomy: An Innovative Approach for Removal of Impacted Kuntscher Nail

ABSTRACT The use of Kuntscher nail has been one of the most important advancement in trauma surgery. Removal of impacted Kuntscher nail represents one of the difficult problems in orthopaedics today. A 53-year-old male p...

Daily Life Challenges in an Earthquake Disaster Situation in Older Adults: A Qualitative Study in Iran

ABSTRACT Introduction: Understanding the challenges of daily life in older adults after a disaster is a necessary precondition to manage the consequences of disasters in this vulnerable group. Aim: The purpose of this st...

Study of Treatment Pattern and Treatment Satisfaction with its Impact on Quality of Life among Psoriasis Patients

ABSTRACT Introduction: Psoriasis is an immune mediated dermatological disorder affecting physical, psychological and social functioning of the individual. Aim: This study explored the pattern of drug use, quality of life...

Download PDF file
  • EP ID EP556230
  • DOI 10.7860/JCDR/2019/37722.12459
  • Views 88
  • Downloads 0

How To Cite

Elham Khoshbin, Sepideh Soheilifar, Zakiyeh Donyavi, Nazanin Shahsavand (2019). Evaluation of Sensibility Threshold of Dental Pulp to Electric Pulp Test (EPT) in the Teeth under Fixed Orthodontic Treatment with 0.014 and 0.012 Initial NiTi Archwire. Journal of Clinical and Diagnostic Research, 13(1), 16-19. https://europub.co.uk/articles/-A-556230