“Evaluation of the Accuracy of Measurements Using Digital Versus Manual Tracing Method In Orthognathic Patients” -A Cephalometric Study

Journal Title: IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) - Year 2017, Vol 16, Issue 9

Abstract

Aim: The aim of this study was to compare pre and post cephalometric measurements in orthognathic patients acquired with digital tracing software (Dolphin 11.0) with equivalent hand traced measurements in regard to the Reproducibility of each method, Accuracy of various soft/hard tissue landmarks, Accuracy of linear measurements, Accuracy of angular measurements. Materials & Methods: The study consisted of 40 lateral cephalometric radiographs of patients treated by orthognathic surgery. Forty cephalograms were traced both manually and digitally by a single examiner. Three analysis namely Steiner’s, Holdaway and Cephalometrics for Orthognathic surgery (COGS) analysis were assessed. The values were analysed using the Leven’s Test. Results: The results showed no statistical significance in measurements using Steiner’s and COGS analysis but significance was seen in Soft tissue facial angle(0.024) and Sub-nasale to H-line (0.055) P value: <0.05 in Holdaway analysis. Conclusion: Conventional and computerized methods showed consistency in all angular and linear measurements. The computer program Dolphin Imaging 11.0 can be used as a reliable aid in diagnosis, planning, monitoring and evaluating orthodontic treatment both in clinical and research settings.

Authors and Affiliations

Dr. Nayeemullah Khan, Dr. Uma Maheswari R, Dr. Ratna Parameswaran, Dr. Nandakumar A, Dr. Ratna Rachel Ponraj

Keywords

Related Articles

Effect of Percutaneous Balloon Mitral Valvuloplasty on Six Minute Walk Test and Left Ventricular Performance by Speckle Tracking Chocardiography in Rheumatic Severe Mitral Stenosis

Background: The effect of percutaneous balloon mitral valvuloplasty (PBMV) on left ventricular function in patients with rheumatic severe mitral stenosis (MS) has been controversial for decades. Our aim is to study the e...

“The Oxygen Prescription” Ozonated win Management of Aggressive Periodontitis

Periodontal disease have been associated with several oral anaerobes such as P. gingivalis , A. actinomycetemcomitans etc. A number of adjuncts have been used to improve the outcome of mechanical & surgical periodontal t...

Nanotechnology in Dentistry- A Review

Nanotechnology is manipulating matter at nanometre level. Applications of nanotechnology for treatment, diagnosis, monitoring, and control of biological systems has recently been referred to as “nanomedicine” by the Nati...

Benign Serous Cyst Adenofibroma Of Ovary – Case report

Ovarian cystadenofibromas are rare benign ovarian tumours in women around fourth to fifth decade of life. They contain epithelial as well as fibrous stromal components.We seek to describe an atypical clinical and radiolo...

Comparative Study of Efficacy of Modified Vacuum Assisted Closure Dressing Using Gloves Versus Betadine Dressing In Chronic Non Healing Ulcer In Govt Rajaji Hospital, Madurai

Background: Vacuum assisted closure dressing is a recent trend and proven method for faster healing of chronic non healing ulcers. Delayed wound healing is a significant health problem imposes social and financial burden...

Download PDF file
  • EP ID EP256732
  • DOI 10.9790/0853-1609097176
  • Views 81
  • Downloads 0

How To Cite

Dr. Nayeemullah Khan, Dr. Uma Maheswari R, Dr. Ratna Parameswaran, Dr. Nandakumar A, Dr. Ratna Rachel Ponraj (2017). “Evaluation of the Accuracy of Measurements Using Digital Versus Manual Tracing Method In Orthognathic Patients” -A Cephalometric Study. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS), 16(9), 71-76. https://europub.co.uk/articles/-A-256732