Abstract

Background: Pancreatic surgery is one of the most difficult and life-threatening surgical therapy especially during necrotizing pancreatitis and advanced solid neoplasms. Aim of the study: To evaluate the possibility to use ECHO Neodymium-Doped Yttrium Aluminium Garnet (ND-YAG) laser in pancreatic surgery and to establish the best power setting for the application on pancreatic tissue. Methods: An ECHO Laser ND-YAG 1064 nm, at the constant fluence of 1800 J/cm2 was used. The laser waves were inserted inside of the samples with optical fibers of 500 micron diameter for a pre-established timing (11 min, 6 min, 4 min) in order to reach the constant fluence. Samples were, then, prepared for hystological examination. Results: At 3W power setting, the pancreatic tissue was not macroscopically modified except for an increased cutting consistency. Histological examination showed no substantial microscopical differences in pancreatic cells that appeared only partially burnt (in fact, nuclei and membranes are still recognizable). The vessels in the surrounding area have the normal morphological aspects. At 5W, macroscopically the presence of a completely burnt area, corresponding to the site of direct interaction of laser and tissue, was found and the surrounding tissue did not appear substantially modified. Histological examination showed the complete absence of cells in the burnt area and an important heat damage of the surrounding cells till the 2th centimeter from the site of laser application. The vessels in the heat damage area appeared completely coagulated. At the power of 7 W, the burnt area was about twice than in the previous setting and histological examination showed the complete absence of cells in the burnt area and a larger heat damage of the nearest cells (till the 4th centimeter from the application site). The vessels in heat damage area were found completely coagulated. Conclusions: A power setting between 4 and 6 W have been found as the best one for laser application on pancreatic tissue because a complete destruction of the cells in the site of application but a limited heat damage in the surrounding healthy cells have been obtained.

Authors and Affiliations

Lorenzo Dioscoridi

Keywords

Related Articles

Effects of Obesity and Diabetes on Beta-Cell Mass in Japanese

The prevalence of type 2 diabetes mellitus (T2DM) continues to increase all over the world. T2DM is characterized by insulin resistance and β-cell dysfunction. Recent studies have shown that β-cell dysfunction, but not i...

Pancreatic Leaks and Fistulae: Pathophysiological Principles

Pancreatic fistula is one of the common complications that may arises after upper gastrointestinal surgery, acute pancreatitis and, more rarely, abdominal traumas. The treatment is mainly based on conservative therapy. H...

The Enigma of Type 3c Diabetes in Chronic Pancreatitis

Pancreatogenic or Type 3c diabetes (T3cDM) is relatively a new entry in the complex world of diabetes study. While the general population and physicians are well aware of type 1 and type 2 diabetes mellitus, as evidenced...

Epithelial-To-Mesenchymal Transition in Pancreatic Ductal Adenocarcinoma: Fiction or Fact?

Pancreatic Ductal Adenocarcinoma (PDAC) is one of the most aggressive and lethal tumors, representing the fourth most common cause of cancer death in the Western world, with an estimated incidence of more than 40,000 cas...

Genetic Therapy for Pancreatic Cancer: Is it the Future?

Although surgery is still the only curative therapy for pancreatic cancer, oncological therapies have started to be more and more promising. We firstly have to consider two important points. The first one is that surgery...

Download PDF file
  • EP ID EP556436
  • DOI 10.17140/POJ-1-104
  • Views 176
  • Downloads 0

How To Cite

Lorenzo Dioscoridi (2016). Evaluation of the Best Power Setting of Laser Waves in Pancreatic Surgery: ECHO ND-YAG Laser Ablation on Bovine Pancreatic Tissue. Pancreas – Open Journal, 1(1), 9-13. https://europub.co.uk/articles/-A-556436