Evaluation of the Efficacy of Clinical Breast Examination Gloves in the Diagnosis of Breast Lumps

Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 6

Abstract

Introduction: Recent studies have questioned the efficacy of mammography in reducing breast cancer-related mortality. Additionally, the efficacies of commercially available gloves marketed as aiding the detection of breast lumps have not been independently verified. Aim: To evaluate the efficacy of clinical breast examination gloves in the detection of breast lumps. Materials and Methods: During the period from October 2011 to June 2012, patients were submitted to clinical examination with and without gloves. This prospective study involved 202 patients who underwent conventional clinical breast examination (test 1) or clinical breast examination with Sensifemme® gloves (test 2). All patients underwent subsequent bilateral ultrasonography (test 3) to confirm the findings of the physical examinations. The Chi-square test was used to compare values, while the kappa concordance index was used to determine the concordance between the diagnostic tests. Results: The mean age of the patients was 43 years; 298 breast lumps were detected. In the clinical examination group (test 1), sensitivity was 54%, specificity was 78%, and accuracy was 57%. These rates for clinical breast examinations with gloves (test 2) were 68%, 58%, and 66%, respectively. The glove increased the diagnosis of breast nodules by 14%; the rate of false-positives was also higher (42% for test 2 compared to 22% for test 1). The accuracy of the glove was found to be superior to clinical examination after 100 patients had been examined. The kappa indices for test 1 vs. test 3 and for test 2 vs. test 3 were 0.15 and 0.16, respectively. Conclusion: Clinical examination using the glove was more effective than clinical examination with bare hands for the diagnosis of breast lumps, as it increased the sensitivity and accuracy of lump detection. However, this was at the expense of a higher false-positive rate, which can lead to further tests, unnecessary biopsies, and patient anxiety. The concordance of clinical examination results (whether performed with or without the glove) with those of ultrasonography is weak. Moreover, the glove has a steep learning curve that may discourage its use in certain circumstances.

Authors and Affiliations

Vanessa Monteiro Sanvido, Andrea Yumi Watanabe, Joaquim Teodoro de Araújo Neto, Simone Elias, Gil Facina, Afonso Celso Pinto Nazário

Keywords

Related Articles

Knowledge and Attitude of Personnel, Key Factors in Implementation of Neonatal Pain Management in NICU: A Qualitative Study

Introduction: Pain management is important, especially for neonates who are not able to verbally express their pain. Therefore, stress reduction and pain management are essential components of neonatal care. Aim: The aim...

Analysis of Xenobiotics Biotransformation and DNA Repair Genes as Factors of Aetiology, Pathogenesis and Criteria of Progression in Children with Congenital Spine Deformities

ABSTRACT Introduction: Spine congenital curvatures formed as a result of anomalies in the development of vertebral bodies leads to severe and rigid deformities of the spinal column in the adolescent age and are often acc...

Primary Adenocarcinoma of the Bulbomembranous Urethra in a 33-Year-Old Male Patient

Primary Urethral Carcinoma (PUC) is considered as a rare tumour, accounts for less than 1% of all malignancies and an incidence rate of four cases per million patients. Incidence increases with the patient’s age and most...

Serological Diagnosis of Indian Tick Typhus in and around Puducherry: Application of Indirect Immunofluorescence Assay

ABSTRACT Introduction: In the past, tick typhus caused by Rickettsia conorii has been reported from different parts of India. However, during the last two decades, reports are few and far between with only some case repo...

Effects of 60° Semi-recumbent Position on Preventing Ventilator-associated Pneumonia: A Single-blind Prospective Randomised Clinical Trial

Introduction: Head-of-Bed Elevation (HOBE) is now considered as a main modifiable factor for decreasing Ventilator-Associated Pneumonia (VAP) especially in the area of intensive care nursing. Despite numerous studies on...

Download PDF file
  • EP ID EP350679
  • DOI 10.7860/JCDR/2017/25504.9987
  • Views 59
  • Downloads 0

How To Cite

Vanessa Monteiro Sanvido, Andrea Yumi Watanabe, Joaquim Teodoro de Araújo Neto, Simone Elias, Gil Facina, Afonso Celso Pinto Nazário (2017). Evaluation of the Efficacy of Clinical Breast Examination Gloves in the Diagnosis of Breast Lumps. Journal of Clinical and Diagnostic Research, 11(6), 1-5. https://europub.co.uk/articles/-A-350679