EVALUATION OF THE MEDIUM VOLTAGE CABLE LINE (SKTM) 20 KV USING TAN DELTA AND PARTIAL DISCHARGE METHODS

Journal Title: Engineering and Technology Journal - Year 2024, Vol 9, Issue 01

Abstract

Distribution network with cable system requires maintenance to maintain the level of reliability. Many factors affect the reliability of this cable system, one of which is environmental factors that can cause deformation of the cable so that it is likely to affect the dielectric condition of the cable. Therefore, to determine and ensure the reliability of the cable system so that it can be known whether a cable is reliable or not, a cable condition diagnostic system is needed that can access the existing cable conditions in the field. Tan Delta (Dissipation Factor) and Partial Discharge are tests that can diagnose the condition of cable insulation in the field based of IEEE standard 400.2 and IEEE standard 400.5.

Authors and Affiliations

Retno Aita Diantari   Restu Ahmad Hidayat

Keywords

Related Articles

APPLYING PRECISION INTO PROACTIVE MAINTENANCE IN NIGERIA ELECTRIC POWER INDUSTRY

Power station plants and equipments are required to run for well beyond their intended lifetime. Opening up machines for inspections is expensive and owners need to consider all relevant information in making the decisio...

STRENGTHENING OF SUBGRADE SOIL BY USING CRUSHED CONCRETE

Recycled aggregates consist of crushed, graded inorganic particles processed from the material that have been used in the constructions and demolition debris. The target of the present work is to determine the strength...

ESTIMATE FRICTION FACTOR FOR POLYPROPYLENE PIPES

The major losses of fluid flow in plastic pipes due to friction are usually few or negligible in some cases, and this is due to the assumption that the value of the friction factor is small (small roughness). This work a...

A COLOUR SCHEME AUTHENTICATED TUTOR BOOKING WEBSITE

Authentication is the first and most important step in information security. Traditional password authentication systems are not strong enough to cope with the current age of cybercrime because passwords can be easily pr...

Portable 5.8ghz FPV System with Smartaudio

The Portable FPV System with Smartaudio is a method used simply to control a radio-controlled vehicle specifically those that use Unmanned Aerial Systems (UAS) or other type of Unmanned Aerial Vehicles (UAV) in the drive...

Download PDF file
  • EP ID EP727441
  • DOI 10.47191/etj/v9i01.09
  • Views 17
  • Downloads 0

How To Cite

Retno Aita Diantari   Restu Ahmad Hidayat (2024). EVALUATION OF THE MEDIUM VOLTAGE CABLE LINE (SKTM) 20 KV USING TAN DELTA AND PARTIAL DISCHARGE METHODS. Engineering and Technology Journal, 9(01), -. https://europub.co.uk/articles/-A-727441