Evaluation of the steam sterilization quality and assessment of knowledge, attitude, and practice of clinical directors regarding infection control in dental clinics: A cross-sectional study in Mashhad, Iran

Journal Title: Environmental Health Engineering and Management Journal - Year 2020, Vol 7, Issue 4

Abstract

Background: The sterilization cycle is one of the most important parts of infection control. Accordingly, the present study was conducted to assess the quality of steam sterilization and compare the knowledge, attitude, and practice of clinical directors in dental clinics, based on the experimental work in one of the most important and famous dental departments and clinics in the Northeast of Iran. Methods: This cross-sectional study was conducted from June to September 2017 in 84 dental outpatient clinics of Mashhad, Iran. The status of sterilization quality was evaluated using biological (BI) and chemical indicators (CI) and the results of a questionnaire. The participants include the technical manager and operator of the Autoclave, who were included in this study according to the inclusion criteria by stratified cluster sampling. Information on their knowledge, practices, and attitudes were evaluated. Also, BI and CI were used to evaluate the autoclave accuracy. The data were analyzed by Mann-Whitney U, Wilcoxon signed-rank, and Fisher’s exact tests using SPSS (Version 19, SPSS Inc., Chicago, IL, USA). Results: In this study, the results of 69 (82.1%) biological test were negative. Based on the questionnaire results, 64 (76%) clinics used CI, and only 4 (5%) clinics used CI and BI to evaluate the sterilization quality. The mean scores of attitude (P = 0.001), knowledge (P = 0.001), and practice (P < 0.001) of the technical manager in dental clinics were significantly higher than those in outpatient clinics. Also, there was a significant association between the knowledge and practice of the clinics’ technical managers (P < 0.001). Conclusion: According to the results, 93.3% of the clinics that had a positive biological test were outpatient clinics. Also, it was revealed that insufficient knowledge, attitude, and practice lead to imperfect sterilization. Also, the mean score of dentists was higher than that of general practitioners, therefore, in addition to suggesting training programs for managers, it is recommended that employ a dental practitioner as the technical manager of outpatient clinics. In order to control infection in clinics, it is recommended to monitor the sterilization process in clinics according to the instructions of the monitoring units.

Authors and Affiliations

Javad Sarabadani , Negin Rahati , Kiarash Ghazvini , Ali Labafchi, Sedighe Karbasi , Negin Jabbari, Fatemeh Aminizade

Keywords

Related Articles

Nitrogen removal by floating constructed wetland: Decontamination of the Buriganga River

Background: Buriganga is considered as one of the most important river in the country. But, its water quality has changed dramatically, which is responsible for creating unfavorable conditions for aquatic life. The mai...

Treatment of tofu liquid waste using anaerobic-aerobic biofilm aeration system to reduce pollution

Background: Tofu derived from processed soybeans is popular among the public, but its production has an unfavourable effect. After all, it produces liquid waste that causes quite high pollution because it contains quit...

Peptides on a rescue mission against the hazardous cidal chemicals used in Eastern Indian Agriculture: An in-silico approach based on field survey in 2020

Background: The use of poisonous agrochemicals is both necessary and menacing for a farmer. The long-term hazards of chemicals can even be life-threatening to many people. Recently, the adverse effects of such chemical...

Biomonitoring of heavy metal signatures in urbanized contaminated ecosystems of Southern India: A case study using raptor, Athene brama

Background: Heavy metals remain tenacious in the environment which further leads to emerging bioaccumulation, rising through the food chain. Birds are great environmental sentinels that can spot even the smallest chang...

Evaluation of the efficiency of the TiO2/UV nano-photocatalytic process in the removal of humic and fulvic acids from aqueous solutions

Background: Removing natural organic substances from drinking water sources is necessary to prevent the formation of toxic and carcinogenic disinfection by-products (DBPs). The nano-photocatalytic oxidation process to...

Download PDF file
  • EP ID EP691217
  • DOI -
  • Views 145
  • Downloads 0

How To Cite

Javad Sarabadani, Negin Rahati, Kiarash Ghazvini, Ali Labafchi, Sedighe Karbasi, Negin Jabbari, Fatemeh Aminizade (2020). Evaluation of the steam sterilization quality and assessment of knowledge, attitude, and practice of clinical directors regarding infection control in dental clinics: A cross-sectional study in Mashhad, Iran. Environmental Health Engineering and Management Journal, 7(4), -. https://europub.co.uk/articles/-A-691217