Ex vivo Analysis of Three Electronic Apex Locators Accuracy with Different Settings
Journal Title: Journal of Advances in Medicine and Medical Research - Year 2016, Vol 16, Issue 11
Abstract
Aims: The correct determination of a root canal length is a fundamental step for an adequate chemical-mechanical preparation and consequently, for a successful endodontic treatment. Electronic apex locators (EAL) were developed to provide fast and reliable working lengths. The aim of the present study was to analyze the accuracy of the Root ZX II, RomiApex A-15, and SmarPex EAL’s to determine the location of apical constriction, with and without the instructions recommended by the manufacturers. Methodology: Fifteen mandibular premolars were randomly selected and root canals were accessed. The real canal length was determined by introducing a #15 K-file until the tip was visualized in the apical foramen, using 40x magnification of an operative microscope. In the sequence, the teeth were inserted in plastic flasks containing floral foam soaked in 0.9% saline solution. The root canals were filled with 1% sodium hypochlorite and the electronic measures were obtained with the selected devices until the “0.0” or the last green bar mark, as showed in devices display, and as per the manufacturers settings recommendation. The data were submitted to statistical analysis with the Friedman and Wilcoxon tests with a 0.05% significance level (p < 0.05). Results: All devices were similar (p > 0.05) and showed precise and acceptable measurements at both times. Without manufacturers setting recommendation, the Root ZX II was the EAL that presented the greater percentage of coincidences with the real teeth length measures (73.33%), followed by the RomiApex A-15 (66.66%) and the SmarPex (40%). After performing the recommended settings the Root ZX II and the SmarPex presented 86.66% of coincidence with the real length, however, only the SmarPex device enhanced the mean precision with the real length (p < 0.05). Conclusion: Considering a clinically acceptable average error of ±0.5 mm, all devices were effective in determining the measurement until the apical constriction. Although, there were no statistical significant difference with and without manufacturers instruction, for Root ZX II, the performance was better when manufacturer instructions were followed.
Authors and Affiliations
Antonio Batista, Gilson Blitzkow Sydney, Marili Doro Andrade Deonizio, Thais Cristina Pereira, Carolina Carvalho de Oliveira Santos, Bruno Cavalini Cavenago
Association of Posterior Reversible Encephalopathy Syndrome with Renal Failure
Background: Posterior reversible encephalopathy syndrome is a clinico-radiological entity that is characterized by variable associations of seizure activity, consciousness impairment, headaches, visual abnormalities, nau...
Chromogranin-A Levels and Refractory Bronchospasm in Interstitial Lung Disease: A Preliminary Report on the Favourable Response to Octreotide
Aims: A wide variety of lung pathologies are associated with pulmonary neuroendocrine cell hyperplasia (PNECH). Presentation of Case: We report two patients with interstitial lung disease (ILD), severe persistent bronch...
Safety and Efficacy of Prolonged Hydroxycarbamide Administration in Patients with Sickle Cell Disease in Northwestern Greece
Hydroxycarbamide (HC) is a ribonucleotide reductase inhibitor which promotes fetal hemoglobin (HbF) induction and has proven efficacy in sickle cell disease (SCD) patients. Given its mechanism of action and prior reports...
Calcifying Cystic Odontogenic Tumor: A Diagnostic Challenge
The calcifying odontogenic cyst was first described by Gorlin et al in 1962 and has been referred to as “Gorlin’s cyst” or “Calcifying ghost cell odontogenic cyst”. The lesion has cystic as well as tumor-like elements an...
Isoflurane and Ketamine/Xylazine Anesthesia do not Influence the Neuroprotective Effects of Simvastatin in a Model of Permanent Cerebral Ischemic Injury in C57BL/6J Mice
Laboratory mice with Middle Cerebral Artery Occlusion (MCAO) represent the main animal models for ischemic stroke research. Appropriate anesthetic protocols are essential, as anesthetic agents might affect the central ne...