Ex vivo Analysis of Three Electronic Apex Locators Accuracy with Different Settings

Journal Title: Journal of Advances in Medicine and Medical Research - Year 2016, Vol 16, Issue 11

Abstract

Aims: The correct determination of a root canal length is a fundamental step for an adequate chemical-mechanical preparation and consequently, for a successful endodontic treatment. Electronic apex locators (EAL) were developed to provide fast and reliable working lengths. The aim of the present study was to analyze the accuracy of the Root ZX II, RomiApex A-15, and SmarPex EAL’s to determine the location of apical constriction, with and without the instructions recommended by the manufacturers. Methodology: Fifteen mandibular premolars were randomly selected and root canals were accessed. The real canal length was determined by introducing a #15 K-file until the tip was visualized in the apical foramen, using 40x magnification of an operative microscope. In the sequence, the teeth were inserted in plastic flasks containing floral foam soaked in 0.9% saline solution. The root canals were filled with 1% sodium hypochlorite and the electronic measures were obtained with the selected devices until the “0.0” or the last green bar mark, as showed in devices display, and as per the manufacturers settings recommendation. The data were submitted to statistical analysis with the Friedman and Wilcoxon tests with a 0.05% significance level (p < 0.05). Results: All devices were similar (p > 0.05) and showed precise and acceptable measurements at both times. Without manufacturers setting recommendation, the Root ZX II was the EAL that presented the greater percentage of coincidences with the real teeth length measures (73.33%), followed by the RomiApex A-15 (66.66%) and the SmarPex (40%). After performing the recommended settings the Root ZX II and the SmarPex presented 86.66% of coincidence with the real length, however, only the SmarPex device enhanced the mean precision with the real length (p < 0.05). Conclusion: Considering a clinically acceptable average error of ±0.5 mm, all devices were effective in determining the measurement until the apical constriction. Although, there were no statistical significant difference with and without manufacturers instruction, for Root ZX II, the performance was better when manufacturer instructions were followed.

Authors and Affiliations

Antonio Batista, Gilson Blitzkow Sydney, Marili Doro Andrade Deonizio, Thais Cristina Pereira, Carolina Carvalho de Oliveira Santos, Bruno Cavalini Cavenago

Keywords

Related Articles

Does the Osteoporosis Dose of Denosumab Really Cause Clinically Significant Hypocalcaemia in CKD 4 and 5

Denosumab is a potent novel antiresorptive agent for treatment of osteoporosis with unique mechanism of action . It is a fully human monoclonal antibody to the receptor activator of nuclear factor-κB ligand (RANKL) that...

Symptomatic Papillary Fibroelastoma- Case Report and Literature Review

Primary cardiac tumors represent a small subset of cardiac neoplasms. The papillary fibroelastoma (PFE) is a benign tumor that typically affects the cardiac valvular system and is second in prevalence only to myxomas. Th...

Gelfoam Embolization - A Preoperative Requisite in Patients with Juvenile Nasopharyngeal Angiofibroma: Report of Three Patients

We present a case series of three patients who were admitted in the ENT department with the complaints of nasal congestion, nasal bleeding and vertigo. Evaluation of these patients revealed juvenile nasopharyngeal angiof...

Sexual Risk Practices of Undergraduate University Students in the Niger Delta Region of Nigeria: Implications for Planning Interventions

Aim: To evaluate the sexual practices of undergraduate university students in the Niger Delta region of Nigeria in order to provide evidence for appropriate interventions. Study Design: A multi-stage random sampling d...

Logistic Regression Analysis of Tooth Loss in a Brazilian Subpopulation

Aims: Evaluating the prevalence of tooth loss, edentulism, prosthetic rehabilitation needs and the use of dental prosthesis as well as determine associations between tooth loss and age, sex, economic classification and r...

Download PDF file
  • EP ID EP341147
  • DOI 10.9734/BJMMR/2016/26477
  • Views 48
  • Downloads 0

How To Cite

Antonio Batista, Gilson Blitzkow Sydney, Marili Doro Andrade Deonizio, Thais Cristina Pereira, Carolina Carvalho de Oliveira Santos, Bruno Cavalini Cavenago (2016). Ex vivo Analysis of Three Electronic Apex Locators Accuracy with Different Settings. Journal of Advances in Medicine and Medical Research, 16(11), 1-7. https://europub.co.uk/articles/-A-341147