Examination of Domestic Cold Water Systems
Journal Title: International Journal of Environment and Climate Change - Year 2016, Vol 6, Issue 2
Abstract
The design of domestic cold water systems is inherently based upon the fixture unit or demand unit method. Therefore, it is fundamentally necessary to understand these water demand units and how to interpret them in order to design efficient water systems that enable a balance between capital cost (where oversizing leads to elevated capital cost) and engineering good practice. Recent sustainability initiatives aimed at reducing water usage encourage the uptake of devices such as flow limiters, spray and percussion taps and low flow appliances and have driven peak water demands down in buildings. Maintaining water movement within the cold water system prevents overheating and helps to maintain a healthy hygienic system. Stagnation exacerbates overheating and may contribute to contamination by micro-organisms. To promote movement of cold water within pipework systems there has been a recent move towards adopting strategies that were not traditionally incorporated into cold water pipework design such as, a secondary cold water return circuit and end of line solenoid flush (dump) valves. These are an added expense, contribute to wasted water or energy and should therefore be carefully considered when incorporating into domestic cold water systems taking cognisance of the other contributory factors such as the building water usage and turnover, building air tightness standards and sanitary ware specification. Also water conservation in buildings is another reason to have an appropriately sized system for the potential water consumption as older appliances had larger flow rates than present; this subsequently has a knock-on-effect on the buildings drainage pipework, system selections and sizing, for example WCs. This paper presents an examination into the importance of sizing a cold water distribution system appropriately and the effect of modern building design standards on operational performance. Finally, through the experience of multiple engineers from many consultancies over several years, a summary of cold water services issues caused in modern buildings is presented and potential strategies to mitigate against excessive temperatures and promote water movement and turnover is given.
Authors and Affiliations
Richard K. Beattie, Damien Kane
Part 1 - Climate Change Adaptation: Water Management and the Built Environment
A changing and more variable climate coupled with urbanization, population growth and shifting living standards has led towards increased frequency of extreme events (droughts and floods). Using water wisely in the built...
Examination of Domestic Cold Water Systems
The design of domestic cold water systems is inherently based upon the fixture unit or demand unit method. Therefore, it is fundamentally necessary to understand these water demand units and how to interpret them in orde...
Influence of Natural and Anthropogenic Processes in the Coastline Evolution at the Doce River Mouth (EspĂrito Santo, Brazil)
Aims and Place: The Doce River is one of the largest rivers of southeastern Brazil, and has been target of strong environmental impact in recent decades due to mining and farming activities. Influenced by lithological fa...
Technical Evaluation of Selexol-Based CO2 Capture Process for a Cement Plant
Cement industry accounts for the second largest emitter of anthropogenic greenhouse gas in the globe with 900 kg CO2 emitted into the atmosphere from producing one tonne of cement. Hence, the effort made to mitigate this...
Monitoring Drainage Water Quality during Green Roof Irrigation Trials Using Synthetic Greywater
Aims: To evaluate the potential for substituting green roof mains water irrigation by irrigation using lightly loaded synthetic greywater. Study Design: The planted green roof system was designed to be operated and teste...