Abstract

In this paper a case of three-layer wall and fitting windows is described. The walls outside layer are made of clinker brick. The public basis is a situation, which occurred in an office building. In this building was a water stain on the windows inside the upstairs part the building, during the rain. In project of the building there were no details of performing three-layer wall and fitting of windows. In Poland one did not described in detail the realization for windows installation in three-layer wall.

Authors and Affiliations

Elżbieta GROCHOWSKA, Antoni MATYSIAK

Keywords

Related Articles

APPLYING RANSAC ALGORITHM FOR FITTING SCANNING STRIPS FROM AIRBORNE LASER SCANNING

During the development of the data acquired by airborne laser scanning the important issue is the fitting and georeferencing of ALS point clouds by means of the tie surfaces and the reference planes. The process of scann...

APPLICATION OF COMPOSITE STRUCTURES IN BRIDGE ENGINEERING. PROBLEMS OF CONSTRUCTION PROCESS AND STRENGTH ANALYSIS

Steel-concrete composite structures have been used in bridge engineering from decades. This is due to rational utilisation of the strength properties of the two materials. At the same time, the reinforced concrete (or pr...

STABILITY OF SELECTED PAHs IN SEWAGE SLUDGE

The aim of the investigations was to estimate the half-life of selected PAHs in sewage sludge. Five hydrocarbons selected from 16 PAHs- EPA were chosen. In this study, the quantity changes in the concentration 3- and 4-r...

PARTIAL FACTORS IN MODELLING OF STEEL STRUCTURES RELIABILITY ACCORDING TO EUROCODES

Problems associated with the estimation of partial factors for structural systems, subsystems and buckling of individual elements are dealt with in this paper. Aspects related to resistance factors for the section resist...

IMPACT OF COMMUNICATION BARRIERS ON URBAN DEVELOPMENT OF NOWOGRÓD BOBRZAŃSKI

Network communication links is an indispensable element of development shaping. Any change in the way of using area should be preceded by an analysis of future impact taking into account the transport capacity. The devel...

Download PDF file
  • EP ID EP243205
  • DOI -
  • Views 51
  • Downloads 0

How To Cite

Elżbieta GROCHOWSKA, Antoni MATYSIAK (2016). EXECUTIVE DISADVANTAGES IN THE LAYERED WALL OF THE FACADE. Civil and Environmental Engineering Reports, 3(22), 55-60. https://europub.co.uk/articles/-A-243205