EXERGETIC DIAGNOSTICS OF A GAS-AND-STEAM POWER PLANT

Journal Title: Civil and Environmental Engineering Reports - Year 2019, Vol 1, Issue 29

Abstract

Evaluation of thermodynamic efficiency of a power plant is usually performed using the method of so-called thermal diagnostics, based on energy balancing. Energetic analysis is however suitable only for a quantitative assessment and for comparing similar technologies. In order to properly assess the origins of energy losses in the given system, an exergetic analysis has to be applied. The paper describes the rules of exergetic diagnostics, which greatly extends the potential of classic thermal diagnostics. A calculation example of a combined cycle power plant is included. The example demonstrates the potential of exergetic diagnostics for locating exergy losses and explains the reasons for increased consumption of fuels by comparing two working conditions of the system: reference and operational.<br/><br/>

Authors and Affiliations

Wojciech STANEK, Tomasz SIMLA

Keywords

Related Articles

FLOOD PROTECTION ON THE ODRA RIVER IN THE SEGMENT BETWEEN NOWA SÓL AND CIGACICE

Existing river valley development methods which have been used for a significant period of time, as well as the use of land for construction of residential developments, have led to negative consequences for the environm...

test

test

Potential and limitations of wastewater reuse in the Hashemite Kingdom of Jordan

Jordan represents a typically water constrained economy that is daily confronted with decisions on its water use. With a fast growing population and an expanding agricultural sector, the demand for alternatives of fresh...

CHEMICAL FORMS OF HEAVY METALS IN BOTTOM SEDIMENTS OF THE MITRĘGA RESERVOIR

Bottom sediments originating from the Mitręga water reservoir were studied. It was assayed, in what chemical forms heavy metals (zinc, copper, nickel, cadmium and lead) occur in sediments, using the method of sequential...

Selected models for the description of the kinematics of changes of height differences between points in a geodesic network under the influence of mining

The article attempts to describe the progress of deformation of the surface of the Legnica-Głogów Copper Mining Area in the years 1967-2008. The state of deformation has been described with kinematical models of the disp...

Download PDF file
  • EP ID EP519274
  • DOI 10.2478/ceer-2019-0001
  • Views 54
  • Downloads 0

How To Cite

Wojciech STANEK, Tomasz SIMLA (2019). EXERGETIC DIAGNOSTICS OF A GAS-AND-STEAM POWER PLANT. Civil and Environmental Engineering Reports, 1(29), 1-17. https://europub.co.uk/articles/-A-519274