EXERGETIC EFFICIENCY SPLIT-CONDITIONERS OF “DAIKIN” FIRM

Abstract

In the modern air-conditioning systems with air split-conditioners, equipments, refrigeration agents and processes are occupied the important place, the objective assessment of the degree of its energy perfection which could be defined only on the basis of their exergy analysis. The purpose of the work is to establish exergetic efficiency and losses of exergy in separate elements of the refrigeration machines of the split-conditioners of “Daikin” firm of different cooling capacity. The author’s innovative mathematical model for the exergetic method for analyzing the work of one-stage refrigeration machines with refrigeration agent R410A, which are used in air split-conditioners of “Daikin” firm model series ATXN-MB, for the purpose of computer evaluation their energy efficiency through exergetic output-input ratio (OIR) depending on the various factors influencing their work, was used in this article. The exergetic OIR of air split-conditioners was determined from its exergy balance for 1 kg/s of the cost of the circulating working refrigerant. The exergetic OIR and losses of exergy in separate elements of the air split-conditioners with standard cooling capacity 2050, 2560, 3410, 5480, 6230 W of “Daikin” firm at standard external temperature conditions are determined. It has been established that with increasing of air split-conditioner cooling capacity the exergetic OIR decreases from 23,1 % to 19,4 %, which is by 16,0 %, what is negative. The losses of exergy in all elements of refrigeration machines of the air split-conditioners are installed, which indicates that elements of the air split-conditioner need to be improved to reduce losses of exergy in them, and the overall increasing in the exergetic OIR.

Authors and Affiliations

Volodymyr Labay, Vitaliy Yaroslav, Oleksandr Dovbush

Keywords

Related Articles

ДИСПЕРСНЕ АРМУВАННЯ СІРЧАНИХ БЕТОНІВ СКЛОВОЛОКНОМ ТА ЇХНЯ ВИТРИВАЛІСТЬ

Disperse reinforcing fibers of different materials and different lengths can significantly effect the basic characteristics of concrete, including increasing compressive strength and tensile, impact strength, wear resist...

МЕТОДИКА ДОСЛІДЖЕНЬ ЗАЛІЗОБЕТОННИХ БАЛОК З ПОШКОДЖЕННЯМИ, ОТРИМАНИМИ ЗА ДІЇ НАВАНТАЖЕННЯ

The research of reinforced concrete beams, in which there is some damage or defects are scare. This is especially applies to studies in which defects arise under the influence of the load, which is due to the complexity...

ВПЛИВ СЕЙСМІЧНИХ ДІЙ НА ЗБІРНІ ЗАЛІЗОБЕТОННІ КОНСТРУКЦІЇ ПОКРИТТЯ ВИРОБНИЧОЇ БУДІВЛІ У м. УЖГОРОД

The need for strengthening of precast concrete structures in service occurs not only in reconstruction cases because of their physical deterioration but also as a result of seismic effects. In seismic regions (Uzhgorod b...

Investigation of air flow in a twin roofs of residential houses

Some kinds of flat roofs with low height of ventilated air gap have certain problems with thermal and moisture regime. The lower surface temperatures of internal constructions in the air gap of roof and presence of hot a...

НАНОМОДИФІКОВАНІ ШВИДКОТВЕРДНУЧІ БЕТОНИ, АРМОВАНІ ДИСПЕРСНИМИ ВОЛОКНАМИ

It is shown that one of the innovative ways of obtaining of Rapid-hardening concretes with enhanced performance for fortifications is the use of nanotechnology techniques related to the directed process of structure form...

Download PDF file
  • EP ID EP494692
  • DOI -
  • Views 73
  • Downloads 0

How To Cite

Volodymyr Labay, Vitaliy Yaroslav, Oleksandr Dovbush (2018). EXERGETIC EFFICIENCY SPLIT-CONDITIONERS OF “DAIKIN” FIRM. Вісник Національного університету "Львівська політехніка". Серія "Теорія та практика будівництва", 0(888), 87-92. https://europub.co.uk/articles/-A-494692