Exergy Performance of the Environmentally Friendly Refrigerant Mixture: R365mfc and R152a

Abstract

This work presents the exergy performance of new environmentally friendly refrigerants 1,1-difluoroethane (R152a) , 1,1,1,3,3-Pentafluorbutane (R365mfc) and particularly their mixture. A vapor compression refrigeration cycle was simulated to see the performance of a single stage cycle at different conditions. A comparative study including a wide range of effective parameters was done. The exergy destruction technique as a new factor for the design of the vapor compression refrigeration cycles was implemented. R365mfc has achieved higher Coefficient of Performance (COP). Furthermore an exergy analysis was employed for every component and for the whole cycle. Among all, the mixtures of R152a and R365mfc have provided higher exergy destruction, power consumption, cooling and heating capacity as compared with the pure fluids.

Authors and Affiliations

Dr. -Ing. Momin E. Abdalla

Keywords

Related Articles

Techniques for Performing User-Defined Integrity Constraint

Integrity constraints help us to maintain integrity i.e., correctness of the table in any database. Whenever a user creates a new database then wrong entry can be inserted in the table. To prevent these wrong entries we...

The Case Study of Swarm Intelligence Optimization Algorithm Performance.

This paper was study in swarm intelligence optimization algorithm performance nature-inspired meta-heuristic algorithm, especially those based on swarm intelligence. Have attracted much attention in the algorithm Partic...

Spectral Analysis of ECG Signal for Detection of Power Line Interference

ECG signal are usually contaminated by noise which can be within the frequency band of interest. This noise arises due to interference between ECG equipment and electromagnetic field of power lines. This contamination c...

ABC & HML Analysis for Inventory Management– Case Study of Sponge Iron Plant

An inventory management is most commonly used technique to manage inventory efficiently in company. The company wants to control their inventory cost, so they used to different type’s inventory techniques to control thi...

An Investigation of Heat Transfer in Vertical Shaft Kiln Process of Cement Manufacture: Part II – Conduction and Radiation

The heat transfer inside the vertical shaft kiln (VSK) for cement manufacture is a complex phenomena involving all the three modes of convection, conduction and radiation heat transfer inside the packed bed moving colum...

Download PDF file
  • EP ID EP19295
  • DOI -
  • Views 290
  • Downloads 6

How To Cite

Dr. -Ing. Momin E. Abdalla (2015). Exergy Performance of the Environmentally Friendly Refrigerant Mixture: R365mfc and R152a. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 3(1), -. https://europub.co.uk/articles/-A-19295