Expansion of the range of wet air I-d diagram for environmental safe heat production

Abstract

For environment protection, condensing boilers may be used instead of emission of high temperature combustion products. For condensing combustion, high moisture content in exhaust gases is typical. I-d diagram can be used for condensing economizer development, but it is primary built for heating, ventilation and air conditioning. In the work, new approach to build I-d diagram is proposed that allow widening of the range of parameters without precision loose. It allows obtaining higher precision for calculation of condensing economizers.

Authors and Affiliations

Volodymyr H. Dziubenko, Viktor O. Mileikovskyi, Illa A. Sachenko

Keywords

Related Articles

French green building rating systems

Most of the Green Building Rating Systems have similarities in common more than differences. All of these systems are trying to integrate issues of environmental protection and health in the building. French Haute Qualit...

Monitoring of potential self-ignition zones of the forest according to cloud cover remote sensing data

The complex analysis of the main properties of natural objects with establishment of extent of interference of their specifics and the factors causing inflaming is carried out. The dominating natural factor forming a loc...

Approaches to building integrated system of municipal solid waste management: classification of packaging waste

In the article the problem concerning packaging waste management was treated, examples of enhanced practice achievement worldwide as to its handling were presented. Key peculiarities of packaging wastes were studied and...

Ecologically clean evaporation-condensation method application for obtaining of electrical contacts based on copper composite materials

In this paper is considered the electron-beam technology on new materials creation, including copper and its alloys, as one of the most promising directions of modern electrometallurgy. The formation process of condensed...

Expansion of the range of wet air I-d diagram for environmental safe heat production

For environment protection, condensing boilers may be used instead of emission of high temperature combustion products. For condensing combustion, high moisture content in exhaust gases is typical. I-d diagram can be use...

Download PDF file
  • EP ID EP497795
  • DOI 10.32347/2411-4049.2018.2.15-22
  • Views 59
  • Downloads 0

How To Cite

Volodymyr H. Dziubenko, Viktor O. Mileikovskyi, Illa A. Sachenko (2018). Expansion of the range of wet air I-d diagram for environmental safe heat production. Екологічна безпека та природокористування, 26(2), 15-22. https://europub.co.uk/articles/-A-497795