Abstract

The increasing the demand of electronics cooling in the field of science, the novel technologies available with us to reduce such type of load on the devices. The pulsating heat pipe (PHP) is one of the advance technologies in electronic cooling application compared to conventional heat pipe. In this experimentation, the performance of single loop pulsating heat pipe was fabricated and tested. The tube of copper material having internal diameter is 2 mm and outer diameter is 3 mm. The PHP was performed on different filling ratio 60% to 80% in steps of 10% and heat input was supplied from 8 W to 16 W in steps of 2 W. The working fluid was used as Acetone and Heptane. The main aim of this experiment is analysis on effect of working fluid and filling ratio on design parameters of single loop pulsating heat pipe and to find out the suitable working fluid for best filling ratio for different heat inputs. The thermal resistance and heat transfer coefficient was evaluated at different filling ratio. The acetone gives the best performance at 60% filling ratio at given heat input as compared to heptane.

Authors and Affiliations

Keywords

Related Articles

Consanguinity among the Muslim Population of Kurnool Town

"Abstract: In humans, consanguineous marriage is frequent in many populations In India consanguinity was more prevalent among Hindus with 33.5% of consanguineous marriages. In the Muslim community, 23.7% of marriages we...

Effects of Physiotherapeutic Techniques and Combination of Physiotherapeutic Techniques with Core Muscle Strengthening Exercises on Stress Urinary Incontinence and Performance in Athletic Event among Collegiate Females

Urinary incontinence affects up to two-thirds of all women. Female athletes who participate in high-impact sports may be at higher risk for urinary incontinence and may lack knowledge of prevention measures. The study ai...

Antimicrobial Efficiency of NaOCL and Helbo Laser against Enterococcus faecalis

Abstract: The aim was to compare the efficacy of antimicrobial therapy, applying photodynamic therapy in different time intervals and the conventional method of irrigation of channel with sodium hypochlorite NaOCl 2.5 %....

A Randomized Controlled Study on Effect of Intravenous Paracetamol as a Pre-Emptive Analgesic In Patients Undergoing Hysterectomy

This study entitled “a randomized controlled study on effect of intravenous paracetamol as a pre-emptive analgesic in patients undergoing hysterectomy” was carried out in Department of Anaesthesiology, Krishna Institute...

The Antagonism of Enterococcus Fecalis Isolated from Kefir with Salmonella Typhimurium Caused Poultry Diarrhea in Vitro

"This study was conducted to investigate the role of Enterococcus Fecalis which isolated from kefir in treatment of diarrhea chicken caused by Salmonella Typhimurium .Enterococcus Fecalis isolated from kefir on azide blo...

Download PDF file
  • EP ID EP367444
  • DOI -
  • Views 126
  • Downloads 0

How To Cite

(2015). Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe. UNKNOWN, 4(4), -. https://europub.co.uk/articles/-A-367444