Although the total hip replacement (THR) is a long-proven method of surgical treatment of diseases and disorders of the human hip, the surgery brings some risk of long-term instability of the joint. The aim of the research was to investigate the cemented bone-implant interface behavior. The main problems (cement layer degradation and bone-cement interface debonding) during physiological loading conditions have been investigated using a custom hip simulator. The experimental setup was designed to allow cyclic loading of the sample of pelvic bone with implanted cemented acetabular component. The hip contact force of required direction and magnitude was applied to the implant using a spherical femoral component head. The most unfavorable activity (downstairs walking) was simulated. The process of damage accumulation in the fixation was monitored by repeated scanning using high resolution micro Computed Tomography (µCT). Use of micro-focus source and large high-resolution flat panel detector allows investigation of structural changes and crack propagation both in the cement layer and the trabecular bone. 

Authors and Affiliations

D. Kytyr, T. Doktor, O. Jirousek, P. Zlamal

Keywords

Related Articles

 Biaxial fatigue behavior of a powder metallurgical TRIP steel

 Multiaxial fatigue behavior is an important topic in critical structural components. In the present study the biaxial-planar fatigue behavior of a powder metallurgical TRIP steel (Transformation Induced Plasticity...

 The research for mechanics stimulation method of nonlinearrandom vibration based on statistical linear theory

 Earthquake disasters have brought great harm to people's life safety and economic property. Itseffect on fabric mainly focus on random effects currently, the general pseudo excitation method could solve theineffici...

 Plasma-sprayed thermal barrier coatings: numerical study on damage localization and evolution

 Thermal barrier coatings (TBCs) are advanced material systems used to enhance performance and in-service life of components operated at high temperatures in gas turbines and other power-generation devices. Be...

 Influence of vacuum carburizing treatment on fatigue crack growth characteristic in DSG2

 The aim of this research is to clarify the influence of vacuum carburizing on the fatigue-crack progress characteristics of DSG2 steel. The test specimen tempering material (QT material) and vacuum carburizing...

 Fatigue life assessment of a non-load carrying fillet joint considering the effects of a cyclic plasticity and weld bead shape

  Fatigue life depends strongly on irreversible contributions that accumulate during cyclic loading and unloading of structures. However, the correct identification of the loading path in terms of uniaxial or multi-...