Experimental Investigation for the Magnetic-Caloric Effect on the Refrigeration Cycle Performance

Journal Title: Scholars Journal of Engineering and Technology - Year 2014, Vol 2, Issue 3

Abstract

The present research aims to investigate experimentally applying of the magnetic-caloric effect on the performance of vapor compression cycle. Three levels of magnetic fields of 1300, 2400, and 3600 Gauss are used and two different locations for the magnetic field; condensate and suction lines are compared. The experimental results are analyzed and verified from thermodynamic point of view. The test results showed that; applying magnetic field at the condensate line or suction line improves the performance of the vapor compression cycle. For magnetic field applying at the condensate line, the coefficient of performance increases by 21.8 %, 29.6 %, and 33.2 % at Gauss levels of 1300, 2400, and 3600 respectively. For magnetic field applying at the suction line, the coefficient of performance increases by 3.6 %, 8.6 %, and 10 % at Gauss levels of 1300, 2400, and 3600 respectively. The magnetic field at the condensate line enhances the coefficient of performance than the suction line. Keywords: Vapor Compression Cycle Magnetic – Magnetic Field – Magnetic-caloric effect

Authors and Affiliations

A Kotb, H. E. Saad

Keywords

Related Articles

Study on the Application of Renewable Energy Sources in Natatorium Building

As a kind of sports building, natatorium is very energy-consuming, because it is large in space and critical in physical environment. The heating of recycled water and the need of air conditioning are the major parts of...

Adsorption studies on tannery wastewater using rice husk

Due to the industrial growth in developing countries like India, the ground water system has been largely polluted, especially heavy metals like chromium which causes severe health problems to human. The removal of such...

Influence of Height - diameter Ratio on Bearing Capacity of GFRP - Steel Double - tube Concrete Column

In this paper, ANSYS finite element software is used to analyze the finite element analysis of four different members with different height-diameter ratio. The influence of height ratio on the ultimate bearing capacity o...

Research on the Mechanism of Viscoelastic Emulsion Flooding

Chemical flooding adopts polymer to realize flow control generally. But section inversion is serious in the late injection and polymer is easily to block oil layers, compounding the difficulty of chemical flooding. In-ho...

Maintenance of an Air Compressor Used in Quarries

The research work investigates the maintenance of an air compressor used in quarries. The objectives of the research were achieved through the selection of a compressor. Reciprocating compressor was selected maintained a...

Download PDF file
  • EP ID EP384365
  • DOI -
  • Views 90
  • Downloads 0

How To Cite

A Kotb, H. E. Saad (2014). Experimental Investigation for the Magnetic-Caloric Effect on the Refrigeration Cycle Performance. Scholars Journal of Engineering and Technology, 2(3), 339-347. https://europub.co.uk/articles/-A-384365