Experimental Research of Coefficient of Local Resistance for Improved Construction of Control Devices in Ventilation System

Abstract

The analysis of theoretical research revealed the need to improve the design of throttling devices for ventilation systems in order to enhance their energy efficiency. An experimental setup is developed for the determination of the local resistance of the throttle device for ventilation system with convenient streamlined by executive working elements. According to the results of experimental studies there is set of local resistance values at different degrees of overlapping area of section of the duct adjusting device conveniently streamlined actuating elements. The graphical dependence for the engineering calculation of the proposed throttling devices is given. The logarithmic characteristic of control is obtained, which ensures smooth flow control in the ventilation system and expansion of the control range. The almost twice decrease of the coefficient of local resistance as compared to traditional throttles shows the possibility of extension of flow control range in air ducts and ventilation systems energy efficiency rise

Authors and Affiliations

G. Ratushniak, R. Stepankovskyi

Keywords

Related Articles

Evaluation оf Microclimate Parameters by Indicators of Local Heat Comfort in the Room Which Has Failures of Outside Observing Structures

The article deals with the task of evaluating the parameters of the microclimate in the room, which has defects of external enclosing structures, using the indicators of thermal comfort PMV (Predicted Mean Vote), PPD (Pr...

Computer Modelling of Temperature Field of Thermal Water in Porous Reservoir

The article presents the results of computer simulation of the temperature field of thermal water in a porous layer. Researches were conducted in the program SolidWorks Flow Simulation. In the work, the method of constru...

Exergy Flow Diagram оf Moist Air For Air Conditioning Systems

The possibility of visual and numerical evaluation of exergy changing in flow of moist air in HVAC systems with the aid of diagrams are presented. Shown a flow diagram of the components of exergy of moist air in co-curre...

Analytical Researches of the Energy Efficiency of Natural Ventilation

The price of all kinds of energy rises, so there is a topical problem of energy efficiency in construction. Estimation of energy efficiency in the natural ventilation with gravitational motive allows more complete calcul...

Influence оf Thermo-Physical Properties оf Biomass оn Methane Formation іn the Household Bioreactors

The construction of domestic continuous action bioreactor has been proposed. The method of engineering calculation was offered to evaluate the performance of biogas plants, including the determination of the maximum numb...

Download PDF file
  • EP ID EP556794
  • DOI -
  • Views 57
  • Downloads 0

How To Cite

G. Ratushniak, R. Stepankovskyi (2017). Experimental Research of Coefficient of Local Resistance for Improved Construction of Control Devices in Ventilation System. Вентиляція, освітлення та теплогазопостачання, 21(), 49-57. https://europub.co.uk/articles/-A-556794