Abstract
Purpose. Development of methodology and experimental studies of the layout of the active screening of technogenic power frequency magnetic fields with different control algorithms with a single coil magnetic executive body. Methodology. In the course of mathematical modeling to determine geometrical size of the magnetic coil executive body based on the size of the protected area, and the configuration of the coil magnetic executive body is determined based on the required uniformity of the magnetic field distribution in the protected area. Results. Experimental studies of open, closed and combined systems of active screening of technogenic power frequency magnetic fields with a single coil magnetic executive body. Originality. For the first time experimentally confirmed the possibility of reducing the level of induction of man-made power frequency magnetic fields in a given area 3-5 times with a single coil magnetic executive body.. The possibility of reducing the level of the magnetic field in a limited area of the space by 15-20 times Practical value. On the basis of the calculations the layout of active screening of technogenic power frequency magnetic fields with different control algorithms with a single coil magnetic executive body has been made.
Authors and Affiliations
B. I. Kuznetsov, T. B. Nikitina, I. V. Bovdyj, A. V. Voloshko, E. V. Vinichenko, D. A. Kotliarov
CALCULATION OF FIELDS IN A COMBINED INDUCTOR SYSTEM AS A TOOLS OF STRAIGHTENING OF METAL COATING OF CAR BODY
In the paper construction of combined inductor system realizing the principle of superposition of circular and plane-parallel magnetic fields is proposed. This inductor system is the instrument of external straightening...
APPLICATION OF HIGH VOLTAGE DIVIDERS FOR POWER QUALITY INDICES MEASUREMENT
Introduction. Determination of power quality indices in high-voltage power grids allows to find the reasons for the deterioration of the power quality. The relevant national and International Standards for power quality...
CORRELATION BETWEEN ELECTRICAL AND MECHANICAL CHARACTERISTICS OF CABLES WITH RADIATION-MODIFIED INSULATION ON THE BASIS OF A HALOGEN-FREE POLYMER COMPOSITION
Introduction. The high saturation of the cable routes of nuclear and thermal stations, wind parks and solar power plants, on-board systems imposes stringent requirements in the field of fire safety of cables, which makes...
FEATURES OF SELECTION OF CAPACITOR BANKS IN ELECTRIC NETWORKS WITH INTERHARMONIC SOURCES
Purpose. Development of a methodology for selecting capacitor bank parameters designed to compensate for reactive power, if there are sources of interharmonics in the electrical network. Development of a methodology for...
ALLOWANCE FOR HEAT AND VIBRATION PARAMETERS VARIATION OF ELECTRIC MACHINES WITH EXTENDED FAILURE INTERVAL
Peculiarities of heat and vibration parameters determination are substantiated for electric machines with extended failure interval under conditions of defects in the main structural units and elements. The necessity of...