Experimental Study of an Air Lift Pump

Journal Title: Engineering, Technology & Applied Science Research - Year 2017, Vol 7, Issue 3

Abstract

In this investigation the effect of submergence ratio and air jacket on the performance of the air lift pump has been studied. Three types of air jackets in addition to five levels of submergence ratios were used. Each air jacket has a number of drilled holes distributed uniformly at the perimeter of the inside pipe, where the total area of drilled holes was kept constant. It has been found that the water flux increases as the submergence ratio increased. Also it was found that the minimum air flux required to start discharging water from the pump decreases as the submergence ratio increases. Air jacket with a hole of 4 mm diameter, resulted the highest performance for the air lift pump.

Authors and Affiliations

F. S. Abou Taleb, J. A. Al-jarrah

Keywords

Related Articles

Optimum Scheme for Insulation System in HV Generator Based on Electromagnetic Analysis

Electrical insulations are one of the basic parts of electrical machinery in any sizes and characteristics. Focusing on insulating, studies on the operation of industrial-electrical machinery came to the fact that the mo...

Improving Power System Stability Using Transfer Function: A Comparative Analysis

In this paper, a small-signal dynamic model of a single-machine infinite-bus (SMIB) power system that includes IEEE type-ST1 excitation system and PSS based on transfer function structure is presented. The changes in the...

Ground Water Quality Assessment of Daur Taluka, Shaheed Benazir Abad

The aim of this study was to assess the ground water quality of Daur Taluka of district Shaheed Benazir Abad for drinking purposes. Forty groundwater samples were collected from different locations and brought to Pakista...

Identifying The Effective Factors for Cost Overrun and Time Delay in Water Construction Projects

Water construction projects in Iran frequently face problems which cause cost overrun and time delay, the two most common issues in construction projects in general. The objective of this survey is to identify and quanti...

Convective Heat Transfer of Al2O3 and CuO Nanofluids Using Various Mixtures of Water-Ethylene Glycol as Base Fluids

In this work, a numerical study has been performed on the convective heat transfer of Al2O3/Water-Ethylene Glycol (EG) and CuO/(W-EG) nanofluids flowing through a circular tube with circumferentially non-uniform heating...

Download PDF file
  • EP ID EP146473
  • DOI -
  • Views 234
  • Downloads 0

How To Cite

F. S. Abou Taleb, J. A. Al-jarrah (2017). Experimental Study of an Air Lift Pump. Engineering, Technology & Applied Science Research, 7(3), -. https://europub.co.uk/articles/-A-146473