Experimental Study of Effect the Load Applied and Length of Adiabatic Section on the Performance of the Wicked Horizontal Heat Pipe.

Journal Title: IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) - Year 2018, Vol 15, Issue 2

Abstract

An experimental study is carried out to evaluate the thermal performance of wicked horizontal heat pipe (WHHP).R134-a is used as working fluid with mass 123 gram. The WHHP was made of three parts condenser, evaporator and adiabatic section. Condenser and evaporator sections were made of copper with 100 mm length, 35 mm outer diameter,24 mm inner diameter and 5.5 mm thickness wall. Adiabatic section was made of UPVC with 100 mm, 43.5 mm outer diameter, 24 mm inner diameter and 9.75 mm wall thickness.The evaporator section of the heat pipe was surrounded by heater coil representing the heat source. The condenser was jacketed with plastic cylinder to accommodate the cooling water flow. The entire WHHP was insulated. WHHPconsists of a copper and UPVC lined with a six-layer stainless steel screen mesh wick with size 100.All the experiments are accomplished and the heat pipe is at the horizontal position (θ=0o). The flow rate of cooling water changed within the range (1, 1.5 and 2) L/M, and heat power applied with range (10, 20, 30 and 40) watt, while all other conditions remained constant. The results show that the thermal resistance decreases when increase the power applied to evaporator while the overall heat coefficient of a heat pipe increased, also the deference temperature between average of evaporator and condenser was increases and the power transferred too.

Authors and Affiliations

Amer I. Ismael, Majid H. Majeed

Keywords

Related Articles

Study of wear behaviour on Hybrid Polymer matrix Composite Materials Used as Orthopedic Implants

This paper constitutes study of wear behaviour of hybrid polymer matrix composites, Prepared of LDPE as matrix and TiO2, CaCO3 and Al2O3 used as reinforcement material with TiO2 constant of 10% in all compositions, were...

Analytical Study of Model Rubberized Concrete Base Isolation System for Buildings in developing Countries

Materials which improve damping and ductility during structural response to earthquakes are very beneficial. Concrete incorporating scrap rubber is one of them. This study analyseddynamicresponse of a 3- bay,4-storey rei...

Emission and Performance testing of single cylinder CI engine with using ricebran biodiesel

The rate of petroleum reserve is declining while energy demand keeps increasing. The current expansion of the Indian economy has escalated petroleum demand, prices have surged, hurting the economies of poor and developin...

Determination of Drag Coefficient for Hyundai Model Using the Strain Gauge Method

The flow field around an automobile is very complex, characterized by a high degree of Three dimensionality, flow separation, reattachment and vortex formation. Flow visualization as well as flow simulation are helpful t...

Intelligent Maintenance System by Using MARKOV Chain with Monte Carlo Simulation Approaches

This paper presents Markov chain technique as a tool for forecasting the suitable maintenance of machines that helps managers in organizational decision making. Markov process is a tool to predict that it can be make log...

Download PDF file
  • EP ID EP437805
  • DOI 10.9790/1684-1502041522.
  • Views 78
  • Downloads 0

How To Cite

Amer I. Ismael, Majid H. Majeed (2018). Experimental Study of Effect the Load Applied and Length of Adiabatic Section on the Performance of the Wicked Horizontal Heat Pipe.. IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE), 15(2), 15-22. https://europub.co.uk/articles/-A-437805