Experimental study of Induced Draft Cooling Tower with Evaporative Pads

Abstract

The cooling towers are used to reject the heat from the water stream to the atmosphere. With the help of the Merkel’s Equation, the optimum water to air flow rate is calculated. Also, by the use of evaporative cooling pads, an additional cooling is obtained. The performance and optimization of the cooling tower is based on the cooling range and approach. To get the most energy efficient operating point of the systems, the optimization of operating conditions of cooling tower applications in cooling water is extremely significant. The objective of this paper is to compare the results derived from the existing setup of an induced draft cooling tower with the towers having evaporative cooling pads attached to it.

Authors and Affiliations

Sourabh Choudhari, Omkar Shitole, Abhishek Parthe, Tejas Mate, Manish Deshmukh

Keywords

Related Articles

A Comparative Study of Centroid-Based and Naïve Bayes Classifiers for Document Categorization

Assigning documents to related categories is critical task which is used for effective document retrieval. Automatic text classification is the process of assigning new text document to the predefined categories based on...

Optimized Design of Switched-Capacitor (SC) Integrator

In this paper we present an optimized design of classical switched capacitor integrator (SC). The operational amplifier utilized in this design implementation is a two stage operational amplifier and a differential folde...

Determination of Fatigue life of Spiral bevel gears used in automotive differential gearbox

This paper describes the experimental destructive testing of spiral bevel gears used in automotive differential gear box. The experimental testing is aimed at early detection of failure of spiral bevel gears during opera...

Recognition of Words in Tamil Script Using Neural Network

In this paper, word recognition using neural network is proposed. Recognition process is started with the partitioning of document image into lines, words, and characters and then capturing the local features of segmente...

Identification of external force acting on a machine or a structure in the case of unknown excitation points

Identification of any external forces acting on a machine or a structure is important for the diagnosis of potential failures or distress. One of the force identification methods is based on the frequency response functi...

Download PDF file
  • EP ID EP393005
  • DOI 10.9790/9622-0712034450.
  • Views 80
  • Downloads 0

How To Cite

Sourabh Choudhari, Omkar Shitole, Abhishek Parthe, Tejas Mate, Manish Deshmukh (2017). Experimental study of Induced Draft Cooling Tower with Evaporative Pads. International Journal of engineering Research and Applications, 7(12), 44-50. https://europub.co.uk/articles/-A-393005