Abstract

The paper presents trends on recent development of possible substitutes for ecological refrigerants from HVAC&R equipment based on thermodynamic, physical and environmental properties and TEWI (Total Equivalent Warming Impact) analysis. This paper contains a good amount of information regarding the environmental pollution produced by the working fluids of the air-conditioning and commercial refrigeration applications to the ecological refrigerant trend. Overall, it is useful for those readers who are interested in current status of alternative refrigerant development related to vapor compression based refrigeration system for air conditioning, heat extraction sources . The study describes the selection of refrigerants adapted for the utilization based on the thermodynamic, physical and environmental properties and explores the studies reported with new refrigerants in domestic refrigerators, air-conditioners, heat extractors, chillers and in automobile air-conditioners. Additionally, a comparative analysis of the TEWI for possible substitutes of refrigerant R134a used in various air-conditioning, heat extraction sources and refrigeration systems is performed effective manner.

Authors and Affiliations

Keywords

Related Articles

Some Certain Properties of a New Class of p-valent Functions Defined by Komatu Operator

: In the present paper ,we introduced a new class W(γ,p,c,A,B,δ,v) of p-valent functions in the unit disk U={z∈C:IzI

Investor Perception on Mutual Fund with Special Reference to Ananthapuramu, Andhra Pradesh

In India Financial Markets provides various investment avenues to the investors. Among the various financial products, Mutual fund ensure the minimum risk and maximum returns to the investors, Mutual fund companies colle...

Implementation of Enhanced Feedback in Automated Latent Fingerprint Matcher

Latent fingerprints are partial impressions of the finger inadvertently left behind on the surface of objects when they are touched or handled. It is not usually visible to the naked eye but may be detected with some che...

Technical Comparison between IPv4 & IPv6 and Migration from IPv4 to IPv6

These days IPv6 over IPv4 tunnels are widely used to form the Global IPv6 Internet. This paper demonstrates the two tunnels and shows when to immigrate from IPv4 to IPV6.Then the risks of immigration are discussed step b...

Cell Phone Tower: A Gift or Curse

Cell Phone Tower: A Gift or Curse

Download PDF file
  • EP ID EP367481
  • DOI -
  • Views 139
  • Downloads 0

How To Cite

(2015). Extraction of Green Energy in R & AC System. UNKNOWN, 4(4), -. https://europub.co.uk/articles/-A-367481