Factors That Impact Evaluation of Left Ventricular Systolic Parameters in Myocardial Perfusion Gated SPECT with 16 Frame and 8 Frame Acquisition Models

Journal Title: Molecular Imaging and Radionuclide Therapy - Year 2018, Vol 27, Issue 2

Abstract

Objective: Evaluating the effects of heart cavity volume, presence and absence of perfusion defect, gender and type of study (stress and rest) on the difference of systolic parameters of myocardial perfusion scan in 16 and 8 framing gated SPECT imaging. Methods: Cardiac gated SPECT in both 16 and 8 framing simultaneously and both stress and rest phases at one-day protocol was performed for 50 patients. Data have been reconstructed by filter back projection (FBP) method and left ventricular (LV) systolic parameters were calculated by using QGS software. The effect of some factors such as LV cavity volume, presence and absence of perfusion defect, gender and type of study on data difference between 8 and 16 frames were evaluated. Results: The differences in ejection fraction (EF), end-diastolic volume (EDV) and end-systolic volume (ESV) in both stress and rest were statistically significant. Difference in both framing was more in stress for EF and ESV, and was more in rest for EDV. Study type had a significant effect on differences in systolic parameters while gender had a significant effect on differences in EF and ESV in rest between both framings. Conclusion: In conclusion, results of this study revealed that difference of both 16 and 8 frames data in systolic phase were statistically significant and it seems that because of better efficiency of 16 frames, it cannot be replaced by 8 frames. Further well-designed studies are required to verify these findings.

Authors and Affiliations

Mojtaba Ansari, Hoda Hashemi, Mehdi Soltanshahi, Mohsen Qutbi, Zahra Azizmohammadi, Faraj Tabeie, Hamid Javadi, Esmail Jafari, Maryam Barekat, Majid Assadi

Keywords

Related Articles

The Role of Pre-ablative Stimulated Thyroglobulin and Thyroglobulin/ Thyroid-Stimulating Hormone Ratio for Predicting Metastasis in Thyroid Cancer

Objectives: In this study, we aimed to investigate the predictive value of pre-ablative stimulated thyroglobulin (Tg) and Tg/thyroid-stimulating hormone (TSH) to identify lymph node metastasis (LNM) or distant metastases...

Splenosis Mimicking Lymphoma Relapse Confirmed by 18F-FDG PET/CT and Tc-99m Nano-colloid Scintigraphy Thirty Years After Splenectomy for Trauma

Splenosis is implantation of the splenic tissue in the abdominal region or elsewhere in the body as a consequence of trauma or splenectomy, which might mimic intra-abdominal involvement of several malignancies. This case...

Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Me...

Super Scan Caused by Parathyroid Carcinoma Observed Both in 18F-FDG PET/CT Scan and Tc-99m MDP Bone Scintigraphy

Super scan is a well-known finding described in skeletal scintigraphy characterized by uniform symmetrically increased radiopharmaceutical uptake by bones and consequently diminished renal parenchymal activity. Sy et al....

Effects of the Use of Automatic Tube Current Modulation on Patient Dose and Image Quality in Computed Tomography

Objectives: The frequency of abdominal computed tomography examinations is increasing, leading to a significant level of patient dose. This study aims to quantify and evaluate the effects of automatic tube current modula...

Download PDF file
  • EP ID EP382204
  • DOI 10.4274/mirt.49368
  • Views 102
  • Downloads 0

How To Cite

Mojtaba Ansari, Hoda Hashemi, Mehdi Soltanshahi, Mohsen Qutbi, Zahra Azizmohammadi, Faraj Tabeie, Hamid Javadi, Esmail Jafari, Maryam Barekat, Majid Assadi (2018). Factors That Impact Evaluation of Left Ventricular Systolic Parameters in Myocardial Perfusion Gated SPECT with 16 Frame and 8 Frame Acquisition Models. Molecular Imaging and Radionuclide Therapy, 27(2), 55-60. https://europub.co.uk/articles/-A-382204