Fatigue behaviour of titanium dental endosseous implants 

Journal Title: Frattura ed Integrità Strutturale - Year 2011, Vol 5, Issue 18

Abstract

In this work two different titanium dental implants are analyzed in order to evaluate their mechanical strength. An ad-hoc designed experimental apparatus is prepared to test against fatigue these implants in a way that approximates as much as possible the actual stresses occurring during mastication motion. The results of these endurance tests are summarized in the form of Wohler-type diagrams showing the duration of a specific implant for different applied loads. These plots show a fatigue limit below which the implants could resist indefinitely. Other aspects of this research concern the influence of a potentially corrosive medium and the analysis of the deformation and failure of the specimens. During fatigue cycling, the titanium implants do not seem to be affected by a more aggressive environment, such as a saline solution. The analysis of the broken specimen allowed the crack initiation sites and the type of fracture propagation to be investigated in depth. In all the considered implants fatigue cracks were seen to initiate preferentially from sites in which the tensile stress concentration is the highest. The results of a finite element analysis performed on one of the specimens is in good agreement with the failure mode observed after the tests. The SEM fracture surface analysis shows a clear similarity between the fracture mode of the tested implants and of the actual implants broken after a certain operating period. 

Authors and Affiliations

Ferdinando Felli, Daniela Pilone, Alessandro Scicutelli

Keywords

Related Articles

 Prediction of the critical stress to crack initiation associated to the investigation of fatigue small crack

  Fatigue design is of vital importance to avoid fatigue small crack growth in engineering structures. This study shows that the critical fatigue design stress can be defined below the usual endurance limit, conside...

 Orientation of propagating crack paths emanating from fretting-fatigue contact problems

 In this work, the orientation and propagation of cracks in fretting fatigue problems is analyzed numerically using the finite element method (FEM) and the extended finite element method (X-FEM). The analysis is p...

 Multi-parameter approximation of stress field in a cracked specimen using purpose-built Java applications

 A quality of multi-parameter approximation of the stress and displacement fields around a crack tip in a non-brittle material test specimen is studied in the paper. The stress field approximation using Williams p...

 Infrared thermography study of the fatigue crack propagation

 The work is devoted to the experimental study of heat dissipation process caused by fatigue crack propagation. To investigate a spatial and time temperature evolution at the crack tip set of experiments was carried...

 Controlling fatigue crack paths for crack surface marking and growth investigations

 While it is well known that fatigue crack growth in metals that display confined slip, such as high strength aluminium alloys, develop crack paths that are responsive to the loading direction and the local micros...

Download PDF file
  • EP ID EP150455
  • DOI 10.3221/IGF-ESIS.18.02
  • Views 58
  • Downloads 0

How To Cite

Ferdinando Felli, Daniela Pilone, Alessandro Scicutelli (2011). Fatigue behaviour of titanium dental endosseous implants . Frattura ed Integrità Strutturale, 5(18), 14-22. https://europub.co.uk/articles/-A-150455