Fault Analysis Using Superconducting Fault Current Limiters

Abstract

Smart grid is an advancement of the existing electrical grid. The key feature of the future smart grid is the decentralization of the main power grid into number of smaller grids (known as micro grids). Interconnection of the distributed generating (DG) sources is required with the existing electrical grid to enhance the reliability of the power system. Extensive integration of DG sources within a smart grid causes failure of a successful implementation of smart grid due to the presence of enormous fault current. Superconducting Fault Current Limiter (SFCL) has the capability to reduce the fault current level within the first cycle of the fault current resulting in an increased transient stability of the power system. In this paper an application of a resistive type SFCL, designed in Simulink / SimPower System has been proposed to limit the fault current that occurs in an interconnected power system. A resistive type SFCL model has been developed in Simulink and the performance of SFCL at different locations has been analysed in the proposed system considering wind farm (10 MVA) as a distributed generating (DG) source with the conventional power plant, to reduce the fault current in micro grids. The feasible location of the SFCL having no negative effect on the DG source has been evaluated in three phase and single line to ground faults at various positions in the smart grid.

Authors and Affiliations

Sneha Rai, Dr. Pankaj Rai

Keywords

Related Articles

AN EXPERIMENTAL INVESTIGATION ON THE STRENGTH PROPERTIES OF FLY ASH BASED BACTERIAL CONCRETE

The present investigation deals with the influence of Bacillus Subtilis bacteria on strength properties of fly ash concrete. In fly ash concrete, cement was partially replaced with 10%, 20% and 30% with fly ash by weight...

A Novel of Nonlinear Voltage Regulators analysis by using Synchronizing and Damping torques

This paper presents an approach to replace the conventional excitation system (AVR+PSS) with a nonlinear voltage regulators derived using synchronizing and damping torque analysis. Now-a- days a keen interest has been de...

Quantitative evaluation and analysis of morphometric parameters derived from ASTER DEM using ARC Hydro tool in a GIS Environment – A study of Vaishali River Basin of Madhya Pradesh

GIS has become a key source to understand the hydrological conditions of watersheds for the last few decades. Arc Hydro tool of ArcGIS has been proven its role in the automated extraction of drainage network and morphome...

Performance of Soft Soil Stabilized by Fly Ash with Natural Fiber Reinforcement as Landfill Cover Layer

The use of clay as a landfill cover system is a choice of alternative materials that are widely used in almost all the existing landfill system in Indonesia and in the world. In addition to the relatively low cost of pro...

Modern LED Street Lighting System with Intensity Control Based on Vehicle Movements and Atmospheric Conditions Using WSN

Street lighting accounts for 53% of outdoor lighting use, and the market is continuously increasing. In the context of rising energy prices and growing environmental awareness, energy efficiency is becoming one of the mo...

Download PDF file
  • EP ID EP180347
  • DOI -
  • Views 232
  • Downloads 0

How To Cite

Sneha Rai, Dr. Pankaj Rai (2016). Fault Analysis Using Superconducting Fault Current Limiters. International Journal of Innovative Research in Advanced Engineering, 0(0), 72-80. https://europub.co.uk/articles/-A-180347