Feasibility and reliability of the FibroScan S2 (pediatric) probe compared with the M probe for liver stiffness measurement in small adults with chronic liver disease

Journal Title: Annals of Hepatology - Year 2013, Vol 12, Issue 1

Abstract

[b]Background[/b]. The success of liver stiffness measurement (LSM) by transient elastography (TE, FibroScan) is influenced by anthropometric factors. In smaller adults, the M probe may fail due to narrow intercostals spaces and rib interference. We aimed to compare LSM using the FibroScan S2 (pediatric) probe with the M probe in small adults with chronic liver disease. [b]Material and methods[/b]. In this prospective study, 41 liver disease patients and 18 controls with a thoracic perimeter ≤ 75 cm underwent LSM using the FibroScan M and S2 probes. TE failure was defined as no valid LSMs and unreliable examinations as < 10 valid LSMs, an interquartile range (IQR)/LSM > 30%, or success rate < 60%. [b]Results[/b]. TE failure was not observed and reliability did not differ between the M and S2 probes (86% vs. 95%; P = 0.20). Liver stiffness measured using the M and S2 probes was highly correlated (ρ = 0.81; P < 0.0005) and median liver stiffness did not differ between probes (4.5 vs. 4.4 kPa; P = 0.10). However, in participants with a skin-capsular distance ≥ 15 mm, median liver stiffness was higher using the S2 probe (5.5 vs. 4.9 kPa; P = 0.008). When compared with validated liver stiffness cut-offs, the S2 probe would have overestimated the stage of fibrosis compared with the M probe in 10% of patients. [b]Conclusions[/b]. The FibroScan S2 probe does not improve the feasibility of LSM in adults of smaller stature and may overestimate liver stiffness compared with the M probe. The FibroScan M probe should remain the preferred tool for LSM in small adults with chronic liver disease.

Authors and Affiliations

Faruq Pradhan, Farah Ladak, Jenna Tracey, Pam Crotty, Robert Myers

Keywords

Related Articles

Association between metabolic abnormalities and hepatitis C-related hepatocellular carcinoma

Background and aim. Metabolic syndrome is recognised as a potential risk factor for the development of hepatocellular carcinoma (HCC). The association between metabolic factors and hepatitis C (HCV)-related HCC has not...

Liver-specific case fatality due to chronic hepatitis C virus infection: a systematic review

Despite reports that mortality is increasing, overall case fatality due to hepatitis C virus (HCV) is thought to be low. Given the variability in published rates, we aimed to synthesize estimates of liver-specific case f...

Albumin dialysis with molecular adsorbent recirculating system (MARS) for the treatment of hepatic encephalopathy in liver failure

Acute, acute-on-chronic and chronic liver diseases are major health issues worldwide, and most cases end with the need for liver transplantation. Up to 90% of the patients die waiting for an organ to be transplanted. Hep...

Short and long term outcome of kidney transplanted patients with chronic viral hepatitis B and C

Introduction. Liver disease related to chronic viral hepatitis is a major cause of morbidity and mortality in renal transplant patients. There is no agreement upon the influence of chronic hepatitis B (HBV) and hepatitis...

Does HLA-DR7 differentiate the overlap syndrome of auto-immune hepatitis-primary biliary cirrhosis (AIH-PBC) from those with auto-immune hepatitis type 1?

Introduction. Autoimmune hepatitis (AIH) and overlap-syndrome (OS) are autoimmune liver diseases of unknown etiology. Although HLA-DR3/DR4 plays a susceptibility role in AIH but there is limited information in regard to...

Download PDF file
  • EP ID EP78237
  • DOI -
  • Views 122
  • Downloads 0

How To Cite

Faruq Pradhan, Farah Ladak, Jenna Tracey, Pam Crotty, Robert Myers (2013). Feasibility and reliability of the FibroScan S2 (pediatric) probe compared with the M probe for liver stiffness measurement in small adults with chronic liver disease. Annals of Hepatology, 12(1), 100-107. https://europub.co.uk/articles/-A-78237