Feasibility and reliability of the FibroScan S2 (pediatric) probe compared with the M probe for liver stiffness measurement in small adults with chronic liver disease

Journal Title: Annals of Hepatology - Year 2013, Vol 12, Issue 1

Abstract

[b]Background[/b]. The success of liver stiffness measurement (LSM) by transient elastography (TE, FibroScan) is influenced by anthropometric factors. In smaller adults, the M probe may fail due to narrow intercostals spaces and rib interference. We aimed to compare LSM using the FibroScan S2 (pediatric) probe with the M probe in small adults with chronic liver disease. [b]Material and methods[/b]. In this prospective study, 41 liver disease patients and 18 controls with a thoracic perimeter ≤ 75 cm underwent LSM using the FibroScan M and S2 probes. TE failure was defined as no valid LSMs and unreliable examinations as < 10 valid LSMs, an interquartile range (IQR)/LSM > 30%, or success rate < 60%. [b]Results[/b]. TE failure was not observed and reliability did not differ between the M and S2 probes (86% vs. 95%; P = 0.20). Liver stiffness measured using the M and S2 probes was highly correlated (ρ = 0.81; P < 0.0005) and median liver stiffness did not differ between probes (4.5 vs. 4.4 kPa; P = 0.10). However, in participants with a skin-capsular distance ≥ 15 mm, median liver stiffness was higher using the S2 probe (5.5 vs. 4.9 kPa; P = 0.008). When compared with validated liver stiffness cut-offs, the S2 probe would have overestimated the stage of fibrosis compared with the M probe in 10% of patients. [b]Conclusions[/b]. The FibroScan S2 probe does not improve the feasibility of LSM in adults of smaller stature and may overestimate liver stiffness compared with the M probe. The FibroScan M probe should remain the preferred tool for LSM in small adults with chronic liver disease.

Authors and Affiliations

Faruq Pradhan, Farah Ladak, Jenna Tracey, Pam Crotty, Robert Myers

Keywords

Related Articles

Spontaneous HBsAg seroconversion after severe flare of chronic hepatitis B infection

The results of the acute exacerbations of hepatitis B virus are varied from silent to severe acute hepatitis. HBsAg seroconversion induced by either antiviral drugs or occurred spontaneously, as a targeted end point of H...

Usefulness of acoustic radiation force impulse and fibrotest in liver fibrosis assessment after liver transplant

Background and rationale. Acoustic radiation force impulse (ARFI) is a non-invasive tool used in the evaluation of liver fibrosisin HCV positive immune-competent patients. This study aimed to assess the accuracy of ARFI...

Evidence for liver injury in the setting of obstructive sleep apnea

Introduction. Obstructive sleep apnea (OSA) and non-alcoholic fatty liver disease (NAFLD) are both strongly associated with obesity. Whether OSA is an independent risk factor for liver injury is uncertain. Objective. To...

Predictive factors of abstinence in patients undergoing liver transplantation for alcoholic liver disease

Introduction. Alcoholic cirrhosis is one of the most common indications for liver transplantation (LT) inwestern countries. A major concern about transplant patients due to alcoholic liver disease (ALD) is alcoholic reci...

Download PDF file
  • EP ID EP78237
  • DOI -
  • Views 119
  • Downloads 0

How To Cite

Faruq Pradhan, Farah Ladak, Jenna Tracey, Pam Crotty, Robert Myers (2013). Feasibility and reliability of the FibroScan S2 (pediatric) probe compared with the M probe for liver stiffness measurement in small adults with chronic liver disease. Annals of Hepatology, 12(1), 100-107. https://europub.co.uk/articles/-A-78237