Filtration of Harmonic Components and Correction Power Factor in Nonlinear Loads

Abstract

Total harmonic distortion has become an important subject in power quality, especially afteruse of power electronicequipment and non-linear loads. Working of electricity systems smoothly and safety depends on the foundation of quantities such as current and voltage which are sinusoidal and 50 Hz frequency. However, these foundation quantities lose their sinusoidal characteristics because of many reasons and this occurs unwanted harmonics in the system.It is a highly preferred methodto use passive filtersfor reduction harmonic and to improve the power factor. The proposed power system is a combination of three-phase voltage supply, power transformer, six-pulse rectifier, passivefilter, and R-L inductive load. A six-pulse uncontrolled rectifier produces 5th, 7th, 11th, 13th, 17th, 19th, etc. current harmonics components. A passive filter is used to reduce the total harmonic distortion of the input current of the three-phase uncontrolled rectifier. Power system is modeled by using Matlab/Simulink program. Simulation results show that both the harmonics are eliminated and the power coefficient is corrected.Before using passive filters the power coefficient was 0.6877, and the THDI value was measured as 12.71 % in the power system. After using passive filters, the power coefficient was 0.99 and the THDI value was measured as 3.591 % in power system.

Authors and Affiliations

Süleyman ADAK, Hasan Cangi, Ahmet Serdar YILMAZ

Keywords

Related Articles

Array Feed Parabolic Reflector Antennas Design Having Low Near Sidelobe and Backlobe Levels

Antennas which are one of the most important components that designate the system characteristic in radar systems, nowadays have a substantial position in military as well as civil areas. Due to their narrow beamwidth an...

Measurement and Mapping of Long-Term and Continuous Electromagnetic Pollution Levels in a Selected Pilot Region

Mobile phones, mobile devices, the number of users in our daily lives and usage times are increasing rapidly. This rapid increase in both telephone conversations, mobile internet use and mobile systems as well as the rap...

Design of A Two Axis Line of Sight Stabilization System for Vessels

By preventing the angular vibrations of the platform from being carried on to the axes of the attached imaging or laser systems, line of sight stabilization allows both a stable image to be obtained and a stable marker t...

A Goal Programming Model for Multi-Resource Generalized Assignment Problem that Contains Agents With Different Abilities and Priorities Along With Jobs to Be Assigned to the Same Agents

Generalized Assignment Problem (GAP) is assignment of jobs to agents with capacity constraints. For Multi Resource GAP (MR-GAP), as an extension of GAP, each agent has a certain number of constrained resources. The aim o...

Investigation of Micro Structure and Wear Behavior of Particle B4C Particulate Reinforced Composites with AA 2014 Al Matrix

In his study, the composite samples were produced by powder metallurgy method with varying volume fraction (1,2,4 and 8 %) of B4C particles reinforced AA 2014 powder metal alloy. The composite samples were produced with...

Download PDF file
  • EP ID EP491404
  • DOI 10.29109/gujsc.454079
  • Views 111
  • Downloads 0

How To Cite

Süleyman ADAK, Hasan Cangi, Ahmet Serdar YILMAZ (2019). Filtration of Harmonic Components and Correction Power Factor in Nonlinear Loads. Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji, 7(1), 153-164. https://europub.co.uk/articles/-A-491404