Finite Element Stress Analysis of Circumferential Clasp Using Acetal Resin and Chrome Cobalt As Clasp Material

Journal Title: GJRA-Global Journal For Research Analysis - Year 2015, Vol 4, Issue 9

Abstract

Statement of problem: Restoration of esthetics is an important factor to consider in the fabrication of removable partial denture. RPD clasps made from metal cause esthetic problems. Acetal resins have been used as clasp material to improve esthetics. However, there are few FEA studies on acetal resin. Purpose: The purpose of this FEA analysis was to compare stresses induced by acetal resin and cobalt chrome clasp. Material and methods: Stress distribution induced in cast circumferential clasp was evaluated using three dimensional finite element experimental models for acetal and cobalt chromium clasps. Average load of 25 N were applied and stress distribution was evaluated Result: FEA analysis showed the stresses induced by acetal resin clasp and Co-Cr clasp were similar on abutment teeth and bone, however within the clasp acetal resin generated less stress than Co-Cr clasp when downward forces and upward force of displacement were applied. Conclusion: Within the limitations of the study, FEA analysis of cast circumferential clasp with acetal resin and cobalt chrome had induced similar stresses.

Authors and Affiliations

Dr. Lekha K. , Dr Meshramkar R, Dr Harsha BS, Dr Sandhya Rao, Dr Shilpa S, Dr Vani H. M

Keywords

Related Articles

A SOARING GROWTH OF E WALLETS POST DEMONETIZATION – STUDY IN AHMEDABAD

India is traditionally a cash-based economy, with the value of physical currency in circulation estimated to be over 11% of GDP, one of the highest among emerging economies. The government's announcement on demonetizatio...

The Effect of Resistance Training and Swiss Ball Resistance Training on Muscular Strength among Male Handball Players.

The purpose of this study was to find out the effect of Resistance Training and Swiss Ball Resistance Training on Muscular Strength among Male Handball Players. To achieve the purpose of the study, thirty male handball p...

A STUDY OF RETINOPATHY IN PRE DIABETES IN A TERTIARY CARE CENTRE

Diabetes is a chronic disease that has a prolonged prediabetic phase with specific microvasular complications like nephropathy ,retinopathy, neuropathy that can begin during prediabetic phase itself. objective: The stud...

The defect states in the photonic crystal introduce additional modes in the photonic band gap

Introducing a defect layer in photonic crystals lead to additional mode of propagation in the photonic band gap. It can be seen that there is a sharp transmission peak in the gap. The transmission peak is caused by the d...

RESULTS OF COMPOUND DIAPHYSEAL TIBIAL FRACTURES TREATED BY UNREAMED NAIL

Compound fractures of tibia are one of the commonest fractures seen in clinical practice. Traditionally their treatment involved the application of external 􀃶xator and then de􀃶nitive surgery once the wound has healed. Th...

Download PDF file
  • EP ID EP594290
  • DOI -
  • Views 79
  • Downloads 0

How To Cite

Dr. Lekha K. , Dr Meshramkar R, Dr Harsha BS, Dr Sandhya Rao, Dr Shilpa S, Dr Vani H. M (2015). Finite Element Stress Analysis of Circumferential Clasp Using Acetal Resin and Chrome Cobalt As Clasp Material. GJRA-Global Journal For Research Analysis, 4(9), 47-49. https://europub.co.uk/articles/-A-594290