Fixation in the Anterior Mandibular Fracture by Using Titanium Mini-Plates and Stainless Steel Mini-Plates: An Outcome Assessment Study

Journal Title: People's Journal of Scientific Research. - Year 2018, Vol 11, Issue 2

Abstract

This study was conducted to compare the nature and biocompatibility titanium and stainless steel material, and to determine the effectiveness of titanium over the stainless steel mini plates in the management of anteriormandibular fracture.A total of 30 patients were included in the study with symphysis / para-symphysis fracture and were randomly allotted into two groups: Group A included anterior oblique/straight mandibular fracture patients treated using stainless steel mini-plates and screws. Group B, anterior oblique/straight mandibular fracture patient, were treated using titanium mini- plates and screws. The procedure was performed under general anesthesia. The fracture was exposed using a standard incision.The average adaptation time taken for stainless steel mini-plates was 8.42 minutes and 6.04 minutes for titanium mini-plates. Wound dehiscence in case of stainless steel mini-plate was observed in 4 patients from Group A (26.7%) while in the group B it was 0%.Titanium plates were more biocompatible when compared to stainless steel plates as evidenced by the incidence of wound dehiscence. In all cases the plates were found to be rigid, stable and satisfactory for use in the anterior mandibular region.

Authors and Affiliations

Mr. Yogesh Sharma, Prabhat Kumar Soni

Keywords

Related Articles

Juvenile Linear Scleroderma: A Case Report

Linear Scleroderma is a rare type of localized scleroderma which occurs most frequently in childhood, but also may develop in adults. We report a 14 year old female, who on basis of thorough clinical examination was diag...

Endodontic Enigma – Mandibular Second Premolar with Three Root Canals: A Case Report

Location and thorough instrumentation of all the canals in the root of a diseased tooth normally ensure success of the endodontic therapy. Present case was referred for endodontic therapy of mandibular second premolar. C...

Endodontic Trends :Where We Are And Where We Should Be-A Survey Report

A survey was conducted to gather information on methods, materials and attitudes employed in root canal treatment by Dentists and in order to evaluate and improve the quality of current practice. Questionnaire comprising...

Effect of Gabapentin on Pressor Response to Laryngoscopy and Tracheal Intubation: A Double Blind Randomized Placebo Controlled Study

The effects of gabapentin on arterial pressure and heart rate were compared at induction of anaesthesia and at tracheal intubation in a prospective randomized double blind study. Fourty patients of American society of An...

Methemoglobinemia Mimics Complicated Malaria

Methemoglobinemia is an uncommon condition seen in clinical practice. It is generally caused by exposure to drugs, chemicals or solvents. Many drugs are implicated in the causation of Methemoglobinemia one o...

Download PDF file
  • EP ID EP397347
  • DOI -
  • Views 69
  • Downloads 0

How To Cite

Mr. Yogesh Sharma, Prabhat Kumar Soni (2018). Fixation in the Anterior Mandibular Fracture by Using Titanium Mini-Plates and Stainless Steel Mini-Plates: An Outcome Assessment Study. People's Journal of Scientific Research., 11(2), 37-44. https://europub.co.uk/articles/-A-397347