Flexible Intramedullary Nailing for Paediatric Shaft of Femur Fractures – Does the Number of Nails Alter the Outcome?
Journal Title: Malaysian Orthopaedic Journal - Year 2011, Vol 5, Issue 2
Abstract
Background: The use of flexible intramedullary nailing, allowing micro movement at the fracture site, results in excellent outcomes regardless of the number of nails used. We undertook analysis of the outcomes of flexible nailing with reference to the number of nails used. Methods: Twenty patients with diaphyseal femur fracture aged 5-15 years were treated with retrograde flexible intramedullary nailing. The number of nails varied from single to multiple. The results were analysed with regard to the number of nails used. Results: The mean patient age was 7.9 years; patients were followed up for a mean duration of 13.2 months. Those with two and three nails had similar results. Conclusion: A minimum of two flexible nails is needed for optimal fixation in paediatric femur shaft fractures. Also, limiting the number of implants to two is cost effective, decreases operative time, reduces radiation exposure and offers equal results to that of three nails.
Authors and Affiliations
B Kanthimathi, K Arun Kumar
Dynamic Hip Screw Compared to Condylar Blade Plate in the Treatment of Unstable Fragility Intertrochanteric Fractures
Dynamic hip screw (DHS) fixation is considered standard treatment for most intertrochanteric fractures. However, excessive sliding at the fracture site and medialisation of femoral shaft may lead in fixation failure. In...
Outcome of Tibial Fractures Cleaned and Irrigated with Tetrachlorodecaoxygen Solution and Primary Plate Fixation
In this study we seek to evaluate the value of tetrachlorodecaoxygen as an intra and postoperative adjuvant in the surgical management of primarily closed tibial fractures fixed with plate and screws. We reasoned that it...
A Technique of Distal Clavicle Fracture Fixation Using The Tightrope Procedure
We present here a technique of fracture stabilization using the Tightrope procedure in a patient with a widely displaced Neer type IIB distal clavicle fracture. The Tightrope system, typically used for stabilization of a...
Highly Crosslinked Polyethylene Tibial Post Fracture in the Unafflicted Limb of a Patient with Unilateral Lower Limb Poliomyelitis: A Case Report
We present a unique case of tibial post fracture of a posterior-stabilised total knee arthroplasty (PS-TKA) using highly crosslinked polyethylene (HXLPE) in the unafflicted limb of a patient who had poliomyelitis. The ti...
Tincture of Benzoin to Prevent Cast Slippage in Clubfoot
Using tincture of benzoin for clubfoot has been well documented in the literature(4,5). The aim of this letter is to recommend and highlight the use of tincture benzoin to prevent clubfoot cast slippage as its use may no...