FLEXURAL ELASTIC BUCKLING STRESS OF BATTEN TYPE LIGHT GAUGE BUILT-UP MEMBER
Journal Title: Civil and Environmental Engineering Reports - Year 2017, Vol 2, Issue 25
Abstract
In Japan, built-up member composed with light gauge is used for studs of shear wall. Flexural buckling stress of built-up compression member is evaluated by effective slenderness ratio. The effective slenderness ratio of light gauge built-up compression member is proposed for heavy sections; however, it is not verified that it can be adopted in light gauge. In this paper, full scale testing of light gauge built-up members are conducted. From the test results, it is shown that current Standard overestimates the buckling strength. Based on energy equilibrium theory, modified effective slenderness ratio for light gauge built-up member is derived. The validity of the modified effective slenderness ratio is shown with test results.
Authors and Affiliations
Kazuya MITSUI, Atsushi SATO
CHANGES TO WATER QUALITY IN THE WATER SUPPLY NETWORK OF ZIELONA GÓRA
The article presents physiochemical parameter changes in water supply network of Zielona Góra. On the basis of the obtained test results, the impact of prolonged retention of water in the network on its quality was deter...
BUILDING RESTORATION OF HISTORIC POOL IN BOLESŁAWIEC: ASSUMPTIONS, DESIGN, REALIZATION
The present elaboration describes realization of project task, entitled: „Retrieving old function in historic swimming pool, at 52 Zgorzelecka street in Bolesławiec”, it has an influence with taking into consideration th...
RENOVATION AND STRENGTHENING OF WOODEN BEAMS WITH CFRP BANDS INCLUDING THE RHEOLOGICAL EFFECTS
The paper presents a work analysis of wooden beams reinforced with glued composite bands from the top and resin inclusions, taking into account the rheology of materials. The paper presents numerical model of the multima...
GLACIOTECTONICALLY DEFORMED LIGNITE DEPOSITS IN THE AREA BETWEEN ŁAGÓWEK AND SIENIAWA, WESTERN POLAND
The Sieniawa Lignite Mine, situated between Łagówek and Sieniawa in western Poland, has been operating for nearly 150 years. This territory was strongly affected by the Scandinavian ice sheets during the Pleistocene. The...
CRACKING IN CONCRETE NEAR JOINTS IN STEELCONCRETE COMPOSITE SLAB
In this paper results of the experimental tests of four full-scale composite steel-concrete elements are reported. In the steel-concrete composite elements, a steel beam was connected with a slab cast on profiled sheetin...