Fracture Mode-Mixity in Symetrical Beam Specimens: FPZ Length Influence
Journal Title: Mašinstvo - Year 2016, Vol 13, Issue 3
Abstract
Mixed-mode fracture in delamination test utilizing double cantilever specimens loaded with bending moments is investigated in the paper. FEM simulations are performed using cohesive zone model where different configurations of test loadings and two critical fracture energy values, ie. two fracture process zone lengths, are considered. Fracture energy partitioning is performed and fracture mode-mixity is determined using simulation results, i.e. mode I and mode II fracture parts in total fracture energy are calculated. The fracture mode-mixities numerically determined for different configurations are compared with results obtained using two analytical fracture energy partitioning theories, according to Williams and to Hutchinson and Suo. An excellent agreement between numerical and the analytical results is observed.
Authors and Affiliations
Josip Kačmarčik, Pejo Konjatić, Aleksandar Karač
The Procedure of Establishing Micro Plant of Renewable Energy Sources and the Profitability
This paper describes the procedure of opening a micro plant for renewable energy sources in Bosnia and Herzegovina, from the idea to the realization of the project, where the steps and acts of obtaining specific document...
Mix Design of Self-Compacting Concrete Containing High Volume Calcareous Fly Ash for Precast Elements
In this paper, the possibility of proportioning self-compacting concrete with high volume calcareous fly ash (W) for precast elements has been investigated. So far, numerous mix design methods for self-compacting concret...
Trends In Maintenance
Maintenance has been changing over the period. Today we are moving to the fourth generation of Industry, where we are talking about great changes in field of production, work and understanding thereof. With device integr...
Influence of contraction shape on the flow quality in wind tunnel test section
Contraction is a part of a wind tunnel that has the greatest impact on the air flow quality in the test section. The constriction ratio, the cross section shape, the length and wall shape are constructive parameters that...
Calculation Index of Reliability on the Example of Steel Hall, Comparation of PTP and EC-1 Regulations for Snow Load
This paper deals with the resistance of the shed of a steel hall in Drvar according to technical regulations for snow from 1961 and EC1 regulations. The paper aims to check the reliability of the shed with probabilistic...