Fraudulent Methods Causing False Negatives In Urine Drug Testing

Journal Title: Biomedical Journal of Scientific & Technical Research (BJSTR) - Year 2019, Vol 14, Issue 1

Abstract

Substance analyzes are carried out to determine drug use. There is a workflow plan that should apply for drug use tests carried out for medico-legal purposes. The most important thing about this is the preservation of urinary integrity. These tests mostly perform for security-sensitive professions or forensic situations. Therefore, drug users try fraudulent ways to hide their dependencies. Easily obtained chemicals are used for his purpose. Examples include nitrite, some commercial products such as peroxide, or household chemicals such as table salt or bleach. Always be aware of adulterants use. Proper monitoring during urine collection will greatly prevent fraudulent conditions. Another important point is to conduct urine integrity tests (pH, nitrite, density, and creatinine). Samples which urine integrity test (pH, nitrite, density, and creatinine) results in an acceptable range should be analyzed. We use immunoassay screening and GC MS validation methods for analysis. Immunoassay screening tests are affected by these adulterants than false negative results obtain due to the deteriorate antigen-antibody relationship. GC-MS verification tests should perform in case of clinical suspicion.The urine drug test has a significant role in monitoring the use of legal and illicit substance [1]. Drug testing programs implement for all security-sensitive professions such as military forces, transport industry, the mining industry. Additionally, health care (facilitate treatment of clinical intoxication and rehabilitation programs), detect doping in sports, legal and criminal situations such as postaccident testing, rehabilitation testing of ex-convicts, are common areas for drug testing [2]. Drug testing screening programs are increasing day by day. Urine, blood, hair, saliva, sweat and nail samples are using for substance abuse screening tests. Depending on the method of measuring drug levels, screening tests have different specificity, sensitivity, and accuracy of each sample. The most frequently preferred sample for substance abuse screening test is urine because of its easy collection. Furthermore, urine has longer detection times and higher drug concentrations than blood [3]. At the stage of giving the urine sample can be easily cheated. Illegal drug users try to hide their substance use with adulterants (in vivo or in vitro). In vivo adulteration involves the dilution of urine with water or taking a diüretic substance for increasing the metabolism.In vitro adulteration is the act of adding foreign chemicals (such as vinegar, table salt, hypochlorite bleach, laundry detergent) to urine samples. Therefore, in order to prevent false negative results, the urine validity tests are used [4]. Studies have been carried out for many years to prevent false negative results by detecting adulteration action to the urine. For this purpose, urine specimen intake and admission procedures were developed. Surveillance of urine collection is the most important step. If we make this step meaningfully, we prevent urinary substitution and in vitro adulteration.

Authors and Affiliations

Soycan Mizrak

Keywords

Related Articles

Scapula Osteosarcoma

Although conventional osteosarcoma is one of the most common type of primary bone malignancy but fibroblastic subtype is rare enough to push us to report this case. We had experience with scapulectomy for conventional os...

Medical Database for Detecting Neoplastic Lesions in Human Colorectal Cancer with Deep Learning

Medical databases are fundamental for developing new techniques for early detection of neoplastic cells. They are however difficult to obtain, since the labelling of the images is often operator dependent, requires speci...

Küttner’s Tumour - Chronic Sclerosing Sialadenitis of the Submandibular Gland

Chronic sclerosing sialadenitis, originally described by H. Küttner in 1896, is a rare cause of salivary gland enlargement [1]. Its clinical and radiographic presentations can mimic other conditions such as, lymphoma or...

When Angiography Makes a Difference - Polyarteritis Nodosa- A Rare Cause of Mid- Gastrointestinal Bleeding

We present a case of overt and recurrent mid-gastrointestinal bleeding with hemodynamic repercussion and severe limitation to the patients’ quality of life, followed in our department for the last 6 years. The final diag...

Sturge-Weber Syndrome Complicating with Ipsilateral Hemangioma-liked Nasal Polyps

Sturge-Weber Syndrome Complicating with Ipsilateral Hemangioma-liked Nasal Polyps: Sturge-Weber syndrome (SWS), also known as encephalotrigeminal angiomatosis, was reported by Schirmer, Sturge and Weber in succession in...

Download PDF file
  • EP ID EP587595
  • DOI 10.26717/BJSTR.2019.14.002481
  • Views 140
  • Downloads 0

How To Cite

Soycan Mizrak (2019). Fraudulent Methods Causing False Negatives In Urine Drug Testing. Biomedical Journal of Scientific & Technical Research (BJSTR), 14(1), 10335-10337. https://europub.co.uk/articles/-A-587595