FREQUENCY INDEXES OF RESPIRATION DURING INTERRUPTER EXPERIMENT

Journal Title: Metrology and Measurement Systems - Year 2008, Vol 15, Issue 2

Abstract

A new issue of the respiratory mechanics evaluation by the frequency mode of the interrupter technique is undertaken in the paper. The aim of the computer-aided research is to show the abilities to separate airways and tissue properties of the respiratory system. The proposed evaluation procedure of the identification quality in the modified DuBois model proves the possibility to conduct repeatable measurements of the important diagnostic indexes. The obtained precision of the parametric description of the investigated physiological system suggests the need to continue the work in the outlined direction. Their final effect can be a portable device with applicability to clinically diffcult subjects - infants and pre-school children.

Authors and Affiliations

IRENEUSZ JABŁOŃSKI, ANUSZ MROCZKA

Keywords

Related Articles

REVIEW OF THE BOOK: WALDEMAR NAWROCKI, INTRODUCTION TO<br /> QUANTUM METROLOGY (IN POLISH)

Quantum metrology is a field of theoretical and experimental study of high-resolution and high-precision methods of measurement of physical parameters based on quantum mechanics, and particularly exploiting quantum entan...

UNCERTAINTY EVALUATION OF THE PROCESSING ALGORITHM OF A TIME-VARIABLE QUANTITIES IN MULTI-CHANNEL MEASUREMENT SYSTEMS

In this paper the application of the generalised law of uncertainty propagation in determining the standard uncertainty of measurement in a multi-channel sampling transducer has been proposed. It has been shown that for...

HE INFLUENCE OF THE BALL MATERIAL ON THE BRINELL HARDNESS

A Brinell hardness tester with carbide and steel balls was calibrated and thereafter the hardness of ten samples of steel STN 41 1600 was measured by four appraisers. The uncertainty of calibration and of the hardness me...

MEASUREMENT METHOD OF SHAPE DEVIATION OF CYLINDRICAL MICRO-LENSES USING FOCUSED LASER BEAM AND REFERENCE AXIS<br />

Constant progress in application of micro-lenses in many modern optical systems caused a continuous increase of the need to investigate methods of their measurement. A new method of measurement of shape deviation of such...

MULTITASKING MEASURING SYSTEM OF THE BACKING CALORIMETER FOR THE ZEUS EXPERIMENT AT THE HERA ACCELERATOR<br />

The paper is devoted to the subject of application of a complex measurement system in HEP experiments. The measurement system is electronic, FPGA-based, multi-channel and distributed. The application is the Backing Calor...

Download PDF file
  • EP ID EP83124
  • DOI -
  • Views 98
  • Downloads 0

How To Cite

IRENEUSZ JABŁOŃSKI, ANUSZ MROCZKA (2008). FREQUENCY INDEXES OF RESPIRATION DURING INTERRUPTER EXPERIMENT. Metrology and Measurement Systems, 15(2), 153-164. https://europub.co.uk/articles/-A-83124