Glycerol trinitrate. Application of gas chromatography with electron capture detection in analysing in air samples

Journal Title: Podstawy i Metody Oceny Środowiska Pracy - Year 2013, Vol 29, Issue 4

Abstract

This paper describes a fully validated method for analysing glyceryl trinitrate (nitroglycerin) with gas chromatography with electron capture detection (GC/ECD). The lowest concentration of glyceryl trinitrate, which can be determined with this method is 0.007 mg/m3. The use of RTX-5MS capillary column makes it possible to determine glyceryl trinitrate in the presence of ethylene glycol dinitrate. This method is based on collecting glyceryl trinitrate on a sorbent tube filled with silica gel. The method of determining glyceryl trinitrate has been recorded as an analytical procedure, which is available in the Appendix.

Authors and Affiliations

JOANNA KOWALSKA

Keywords

Related Articles

Chlorophenylmethane.Documentation of suggested occupational exposure limits (OELs)

Chlorophenylmethane, commonly known as, benzyl chloride is a colorless liquid with a characteristic acrid and pungent odor. It is a synthetic product obtained due to the reaction between gas chloride and toluene in the p...

Cyklopentan. Oznaczanie w powietrzu środowiska pracy metodą chromatografii gazowej ze spektrometrią mas

W wyniku przeprowadzonych badań opracowano metodę oznaczania cyklopentanu w powietrzu na stanowiskach pracy z zastosowaniem chromatografii gazowej ze spektrometrią mas. Metoda polega na: adsorpcji cyklopentanu w ru...

Hydroquinone. Determination in workplace air

This method describes how to measure hydro-quinone (HQ) in workplace air using HPLC with a diode array detector (DAD). Hydroquinone present in a measured volume of air is collected onto a sulfuric acid-treated silica gel...

Nitropropan. Oznaczanie w powietrzu na stanowiskach pracy metodą chromatografii gazowej

W wyniku przeprowadzonych badań opracowano metodę oznaczania mieszaniny izomerów nitropropanu w powietrzu na stanowiskach pracy z zastosowaniem chromatografii gazowej z detekcją płomieniowo-jonizacyjną. Metoda polega na...

Ethylenediamine. Determination in workplace air with high performance liquid chromatography – spectrophotometric technique

Ethylenediamine (EDA) is a colorless, viscous liquid with ammonia-like odor. It is used as an intermediate in manufacturing chelating agents (EDTA), fungicide, poliamide and formaldehyde-urea resins, surfactants, corrosi...

Download PDF file
  • EP ID EP224512
  • DOI -
  • Views 102
  • Downloads 0

How To Cite

JOANNA KOWALSKA (2013). Glycerol trinitrate. Application of gas chromatography with electron capture detection in analysing in air samples. Podstawy i Metody Oceny Środowiska Pracy, 29(4), 135-148. https://europub.co.uk/articles/-A-224512