Hand Radiograph Analysis and Joint Space Location Improvement for Image Interpretation

Journal Title: Schedae Informaticae - Year 2009, Vol 2009, Issue 0

Abstract

Hand radiograph analysis is extremely exhausting and time consuming for radiologists, not because of the complexity, but because of the precision required during diagnosis. Due to this fact, automatic analysis of the joint space width of all joints in a hand would be indispensable. In the following paper, an improvement of a method used to quantify the minimal JSW in hand radiographs, proposed by the author in his previous works, is considered. The proposed changes have an impact on initial pre-processing and joint space location. As a result of experiments conducted on more than 1100 joint spaces, the overall error of pre-processing and joint location decreases from 10.8% to 2.59% after changes.

Authors and Affiliations

Bartosz Zieliński

Keywords

Related Articles

Hand Radiograph Analysis and Joint Space Location Improvement for Image Interpretation

Hand radiograph analysis is extremely exhausting and time consuming for radiologists, not because of the complexity, but because of the precision required during diagnosis. Due to this fact, automatic analysis of the joi...

Application of Kalman Filter to Noise Reduction in Multichannel Data

The results of application of multichannel Kalman filtering to reduction of uncorrelated noise in magnetotelluric recordings are discussed in this article. Magnetotelluric method of Earth structure recognition is shortly...

Application of an Open Environment for Simulation of Power Plant Unit Operation under Steady and Transient Conditions

The aim of the paper is to present a proposal and discuss an application of an open environment for modeling of a power plant unit. Such an environment is called the Virtual Power Plant (VPP) and is based on a model crea...

THE APPLICATION OF NEURAL SYSTEMS IN VIBRODIAGNOSIS

Vibrodiagnosis helps in detecting incipient faults in rotating machines like pumps and generators. Early detection prevents from undesired breakdown of the machine and allows to schedule maintenance times. The applicatio...

Neural Networks Application to Reduction of Train Caused Distortions in Magnetotelluric Measurement Data

Artificial intelligence methods for MT data processing are proposed. Distortions having a complex structure created by external artificial sources such as, for example, passing train were investigate. In the first part o...

Download PDF file
  • EP ID EP74749
  • DOI -
  • Views 163
  • Downloads 0

How To Cite

Bartosz Zieliński (2009). Hand Radiograph Analysis and Joint Space Location Improvement for Image Interpretation. Schedae Informaticae, 2009(0), 45-61. https://europub.co.uk/articles/-A-74749